IDA8 Global-Net User Manual
84
© 2017, ATEÏS, member of PAX ProAV Group
A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.
Troubleshooting: Replace peripheral device with the error with a working one and contact your
technician to repair the replaced one.
3.1.9.1.17 Ethernet Remote Offline
The IDA8C/S cannot communicate with ethernet peripheral devices such as TerraManger.
Indication:
LED Indicator: When this error is detected, the following LEDs will light up:
o
G. Fault LED on the front panel of the IDA8C/S.
Log:
A text message displays at the touch screen of the IDA8C:
"Ethernet Remote Offline"
A text message displays at the [Machine Fault Record] window in Ateis Studio:
o
TM1: Indicate which customized name triggers fault.
A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.
Troubleshooting: Check the remote communication [Net card or LEDs].
3.1.9.1.18 Ethernet Remote Fault
An error is detected on ethernet peripheral devices. This fault relates to a capsule microphone or a
speaker error such as Terra-K, SDM etc.
Indication:
LED Indicator:
When this error is detected, the following LEDs will light up:
o
G. Fault LED on the front panel of the IDA8C/S.
Log:
A text message displays on the touch screen of IDA8C:
"Ethernet Remote Fault"
A text message displays at the window [Machine Fault Record] in Ateis Studio:
o
TM1: Indicate which customized name triggers fault.
A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.
Troubleshooting: Check the status of the capsule microphone or a speaker.