20.9 Replacing the Piezo Igniter
Figure 20.09.01:
Step 1:
Remove the two (2) 1/4" Tek screws securing the piezo
igniter bracket to the bottom of the fireplace shell.
Figure 20.09.02:
Step 2:
Unplug the wire from the piezo igniter.
Before you begin:
•
Ensure the fireplace is off and cool before servicing
• Ensure the gas supply is turned OFF and disconnect the power supply
•
Flip down the control access cover (see
Section 6.4
)
Figure 20.09.03:
Step 3:
Remove the retaining nut from the back side of the
bracket.
Installation is the reverse of removal.
WARNING:
Servicing of this appliance
must be conducted by a qualified service technician
. Improper servicing, adjustment or
alteration of this appliance may cause property damage, personal injury or loss of life. All servicing should be conducted
with the appliance cold. All replacement parts must be authorized by Ambiance for suitability.