9.0 Minimum Opening Dimensions
The installer must mechanically attach the marking supplied with the gas fireplace insert to the inside of the firebox of the fireplace into
which the gas fireplace insert is installed. See
Figure 9.0.02
.
Cutting of any sheet-metal parts of the fireplace, in which the gas fireplace insert is to be installed, is prohibited except as described in
Section 9.2
.
The fireplace and fireplace chimney must be clean and in good working order and constructed of noncombustible materials. The
chimney clean-outs must fit properly.
WARNING:
This fireplace has been converted for use with a gas fireplace insert only and cannot be used
for burning wood or solid fuels, unless all original parts have been replaced, and the fireplace
reapproved by the authority having jurisdiction.
AVERTISSEMENT:
Ce foyer a ete converti pour utilisation avec un foyer au gaz encastrable et ne peut etre utiliser
pour bruler du bois ou autres combustibles solides a moins que toutes les pieces d'origine ete
remplacees et que le foyer ait ete approuve de nouveau par l'autorite competente.
303-0123
Figure 9.0.02:
Figure 9.0.01:
WARNING:
Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this
appliance may result in property damage or personal injury.
The following opening dimensions show the absolute minimum opening size allowable for the 22-DVIM22LN-1. This appliance may be
configured to accommodate a variety of openings and aesthetic preferences.
Depending on the configuration of the surround, the minimum opening dimensions may change. Refer to
Section 9.1
for installation
options.
SIDE VIEW
TOP VIEW
Min flue size required 4" (10.2 cm) x 7" (17.8 cm) unless
reducer kit 22-LKF2 is used*.
See
Section 13.3
.