background image

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.

B Y :   S H E R W O O D   I N D U S T R I E S   L T D

OWNER’S MANUAL

PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

EG40-071

EG40 BV

This appliance may be installed in an after market permanently 

located, manufactured  (mobile) home, where not prohibited by 

local codes.

This appliance is only for use with the type of gas indicated on the 

rating plate. This appliance is not convertible for use with other 

gases, unless a certified kit is used.

WHAT TO DO IF YOU SMELL GAS

• Open windows/Extinguish any open flame.

• Do not try to light any appliance.

• Do not touch any electrical switch or use any phone in your 

building.

• Immediately call your gas supplier from a neighbour’s phone. 

Follow the gas supplier’s instructions.

• If  you  cannot  reach  your  gas  supplier,  call  the  fire 

department.

WARNING

If the information in this manual is not followed exactly, a fire or explosion may 

result causing property damage, personal injury or loss of life. Installation and 

service must be performed by a qualified installer, service agency or the gas supplier.

FOR YOUR SAFETY

Do not store or use gasoline or other Flammable vapours and liquids in the vicinity of 

this or any other appliance.

Massachusetts  installations  (Warning):  This  product  must  be  installed  by  a  licensed 

plumber or gas fitter when installed within the Commonwealth of Massachusetts. Other 

Massachusetts  code  requirements:-Flexible  connector  must  not  be  longer  than  36 

inches, shut off valve must be a “T” handle gas cock, only direct vent sealed combustion 

products are approved for bedroom/bathrooms, fireplace dampers must be removed or 

welded in the open position prior to the installation of a fireplace insert or gas log.

Summary of Contents for EG40 BV LPG

Page 1: ...he gas supplier s instructions If you cannot reach your gas supplier call the fire department WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Installation and service must be performed by a qualified installer service agency or the gas supplier FOR YOUR SAFETY Do not store or use gasoline or ot...

Page 2: ...llation code Canada or National Fuel Gas Code ANSI Z223 1 2 USA To prevent injury do not allow anyone who is unfamiliar with the stove to operate it To prevent injury if the pilot or pilot and burners have gone out on their own open the glass door and wait 5 minutes to air out before attempting to re light the stove Always keep the area around this appliance clear of combustible material gasoline ...

Page 3: ... 7 Installation Into An Existing Chimney 7 Straight Vertical Installation 8 Electrical Requirements 9 Replacing The Blower 10 Adjusting The Venturies 10 Fuel Conversion 11 Gas Line Connection and Testing 12 Secondary Installation 13 Installation of Log Set and Embers 13 Operating Instructions 15 Lighting Instructions 15 Turning Gas Off To Appliance 15 Routine Maintenance and Service 16 Trouble Sho...

Page 4: ...H ALTITUDES CSA P 4 1 02 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY This ENVIRO EG40 BV Fireplace Has been certified for use with either natural or propane gases See rating label Is not for use with solid fuels Is approved for bedroom or bed sitting room IN CANADA must be installed with a listed wall thermostat IN USA see current ANSI Z223 1 for installation instructions Must be inst...

Page 5: ... flue system clearance requirements Locate the stove where it can be accessed by a gas supply line Locate the stove in a large and open room that is centrally located in the house This will optimize heat circulation and comfort As the stove is equipped with a convection fan ensure that an electrical outlet is within 6 feet 1 8 m of the stove The flow of combustion and ventilation air must not be o...

Page 6: ...em designed to protect against improper venting of combustion products This safety switch is located on the rear of the appliance close to the drafthood relief opening If the switch trips more than once the chimney should be inspected by a qualified service technician for possible blockage or severe down draught conditions MANUFACTURER S GENERAL VENTING GUIDELINES This information is compiled by t...

Page 7: ... This basic venting configuration shown are rough guidelines only Follow national and local codes for other installation options Measure the height of the chimney beforehand and purchase the appropriate kit Never attempt to over stretch a flexible liner to accommodate the height of the chimney Any flue damper must be removed or locked permanently in the open position The chimney must be clean in g...

Page 8: ... accounts for 5 feet 1 5 m of the horizontal run The venting should never slope down a minimum 1 4 inch 0 6 cm rise is needed for every 2 feet 61 cm of horizontal is recommended If practical it is best to locate the appliance to permit the use of shorter horizontals and fewer elbows Number of 90 elbows Maximum total horizontal length allowed 2 20 feet 6 1 m 3 13 feet 4 0 m 4 6 feet 1 8 m 5 0 feet ...

Page 9: ...gged directly into a properly grounded three prong outlet DO NOT cut or remove the grounding prong from this plug CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing NOTE Operation of the fan increases the efficiency and the heat output of the appliance The thermostat connects to the...

Page 10: ... tall dark stringy tips are not getting enough air Open the venturi until the flames clean up If the venturi is opened or closed all the way and the correct flames cannot be attained turn off the gas and contact the dealer Warning Incorrect venturi adjustment may lead to improper combustion which is a safety hazard Contact the dealer if there is any concern about the venturi adjustment Initial Ins...

Page 11: ...rsion kit Screw the new injector inside the pilot assembly and re install the hood by placing the hood on the assembly line up the keyway and snap into place STEP 9 Remove the two 2 main burner orifices using a 1 2 deep socket STEP 10 Install the two 2 new orifices supplied making sure that the orifices are in the correct location Be sure to put a bead of pipe thread sealant or approved Teflon tap...

Page 12: ...rom the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 45 KPa Always check for gas leaks with a soap and water solution after completing the required pressure test TO TEST VALVE PRESSURES The pressure taps are located on the left side of the valve Turn set screw 1...

Page 13: ...2 or 15 for proper ember placement DO NOT pack this ember material as this could create an unsafe condition leave embers loose 2 Carefully remove logs from box Check to ensure there is no damage It is very important to install all logs in their proper position to insure safe optimum operating conditions 3 Place the log set into the firebox Locate each log by seating it down onto the burner tray su...

Page 14: ...n on for the first 4 hours This will cure the paint logs gasket material and the other products used in the manufacturing process It is advisable to open a window or door as the unit will start to smoke and can irritate some people After the unit has gone through the first burn turn the unit off including the pilot let the unit get cold then remove the glass door and clean it with a good gas firep...

Page 15: ...nutes to clear out any gas Close door If you smell gas including near the floor STOP Follow B in the above safety information Leak test all gas joints with soapy water NEVER USE AN OPEN FLAME FOR LEAK TESTING If you don t smell gas go to next step 5 Find the pilot located to the right between the front and rear burner 6 Turn gas control knob counter clockwise to PILOT 7 Push the gas control knob i...

Page 16: ...To clean the door use a mild glass cleaner and a soft cloth or a glass cleaner available from your Enviro dealer Abrasive cleaners will damage the glass TO REPLACE DOOR The glass in this appliance is an integral part of the door assembly If the glass is damaged or broken a replacement inner door with glass assembly must be purchased The glass in this appliance is ceramic If the glass is damaged or...

Page 17: ... pilot dies while knob is depressed Bleed line Check gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gas line pressure Check for flame impingement on thermopile If low see Pilot will not remain lit Check thermopile for minimum of 200 mV when burner is switched on Check wiring to thermostat for breaks Flame lifting Leak in vent pipe Check for leaks...

Page 18: ... Stainless Steel Flex Connector with 3 8 Elbow 18 Long EC 024 6 Burner Switch EC 025 7 Miniature Light Bulb 115V EC 031 7 Light Bulb Holder EC 032 Wiring Harness Complete 2 pieces EC 037 Body Wiring Harness EC 037A Burner Wiring Harness EC 037B Fan Control Knob EC 040 IEC Power Cord 115V EC 043 4 oz Bag Coal Embers Only EC 045 8 1 x 1 Side Cabinet Hinge EC 054 Pedestal Door Magnet EC 056 3 8 Tadpo...

Page 19: ...EG40 130 19 Pedestal Door EG40 135 LP to NG Conversion Kit EG40 200 NG to LP Conversion Kit EG40 202 20 Ash Sill EG40 213 21 Door Hinge Set of 2 EG40 302 22 Fan Mount EG40 304 23 Pedestal Box Cover EG40 307 24 Burner Control Assembly NG 30 014 24 Burner Control Assembly LP 30 015 25 Front Pan Burner 30 016 26 Rear Burner with Venturi 30 017 Pilot 1 8 Tube with Ferules 30 043 Log Set Complete 50 08...

Page 20: ...Parts Diagram Chassis EG 40 Body Chassis July 2004 20 ...

Page 21: ...21 Parts Diagram Gas Tray Door EG40 Gas Tray Door Assemblies July 2004 28 9 21 10 24 3 5 6 11 7 12 17 27 26 25 4 ...

Page 22: ...y on all the Electrical Components and Gas Components against manufacturing defects Paint is covered against flaking This offer includes parts and labor for 1 year and for parts only thereafter Your dealer shall make all claims under this warranty in writing WHEN FILING A WARRANTY CLAIM PLEASE COMPLETE THE FOLLOWING INFORMATION ON AN OFFICIAL WARRANTY CLAIM FORM TO THE DEALER Name address and tele...

Page 23: ..._____________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy NATURAL GAS NAT PROPANE LPG INLET GAS PRESSURE _________in wc MAIN BURNER ORIFICE __________ DMS PILOT ORIFICE _________OR________in diam INSTALLER S SIGNATURE ________________________________________...

Reviews: