59
Maintenance
SYMPTOM
ACTION
Sharp blue flames with flames
lifting off the burner at the ends.
1.
Too much primary air. Reduce primary air by closing the primary air shutter. During cold
temperatures, some flame lifting may occur during start-up.
Fan does not turn on.
1.
The fan is thermostatically controlled. It will only turn on when the appliance is warmed-up.
This may take up to 15 minutes with the appliance on high.
2.
Check for 120 VAC electrical supply to the appliance. (Is the cord plugged in?)
3.
Is the fan speed control in the OFF position?
4.
Check for proper mounting of the thermal snap disc.
5.
Check electrical connections.
6.
Check for defective thermal snap disc.
7.
Check for defective fan speed control.
8.
Check for defective fan.
My pilot has gone out after being
lit and stable for several days.
1.
The Harmonia 22 is equipped with one of two possible valves. One of those options includes
a 7 day Pilot on Demand (POD) Timer. This timer will turn the pilot off automatically if there
has been no main burner activity for 7 continuous days. Relight the pilot using the operation
instructions and the pilot will remain lit as long as the main burner is used once every 6 days.
The rating plate included with your fireplace will indicate which valve you have.
See
Section 4
for further information.
All service and repairs should be performed by a qualified and licensed service technician
.