55
Maintenance
20.11 Replacing the Optional Fan Speed Control
Before you begin:
•
Ensure the fireplace is off and cool before servicing
• Ensure the gas supply is turned OFF and disconnect the power supply
•
Flip down the control access cover (see
Section 6.4
)
Figure 20.11.01:
Step 1:
Remove the fan power cord mounting bracket. Remove
the fan speed control / piezo igniter bracket.
Figure 20.11.02:
Step 2:
Remove the knob.
Figure 20.11.03:
Step 4:
Unplug the fan speed control.
Installation is the reverse of removal.
Note:
Fan wires should point down upon install.
CAUTION:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing. This appliance, when installed, must be electrically grounded in accordance with
local codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical code,
CSA C22.1
.
WARNING:
Servicing of this appliance
must be conducted by a qualified service technician
. Improper servicing, adjustment or
alteration of this appliance may cause property damage, personal injury or loss of life. All servicing should be conducted
with the appliance cold. All replacement parts must be authorized by Ambiance for suitability.
Step 3:
Remove the nut securing the fan speed control to the
bracket.
Figure 20.11.04:
Содержание 22-DVIE22LN-1
Страница 64: ......