36
Installation
17.2 Reflective Glass Installation
The following steps highlight the procedure for installing Eternal Flame Reflective Ceramic Glass liner. Handle the panels with
care. Inspect the panels to ensure that no damage has occurred inside the package. Please report any damage immediately to
your Authorized Archgard Dealer. Be sure there are no fingerprints left on the glass panels during install or when cleaning as high
temperatures can bake these prints on permanently.
Before you begin:
• Ensure the gas supply is turned OFF and disconnect the power supply
•
Remove barrier screen (see
Section 14.0
)
•
Remove Glass Door (see
Section 15.0
)
Figure 17.2.01:
Step 1:
Remove the two screws located in the top of the firebox.
These will be used to install the panel clips included with the
panels (see
Figure 17.2.02
).
Figure 17.2.02:
Step 2:
Place the left or right side panel. The longest edge aligns
with the top of the firebox.
Step 3:
Install the first panel clip using a screw removed in
Step 1
.
Figure 17.2.03:
Figure 17.2.04:
Step 4:
Place the rear panel in the back of the firebox, above the
log rest. One end should slip behind the panel already installed.
Figure 17.2.05:
Step 5:
Place the final panel in the firebox and secure it in place
using the remaining panel clip and screw.
Figure 17.2.06: