47
Maintenance
Right: Open air shutter
Left: Close air shutter
20.5 Adjusting the Primary Air
The 22-DVIM22LN-1 includes an air shutter located underneath the firebox of the fireplace which may be used to adjust the primary
air to achieve the ideal flame as shown in
Figure 20.5.01
. To adjust, loosen the wing nut securing the air shutter in place as shown in
Figure 20.5.02
. To open the air shutter and increase air flow to the burner, pull the adjuster to the front of the fireplace. To close the air
shutter and decrease air flow to the burner, push the adjuster to the back of the fireplace.
CAUTION:
Do not adjust primary air below specified opening on the rating plate.
Figure 20.5.01:
Figure 20.5.02:
Lazy yellow flames
Ideal
Short blue flames
Air shutter open too far
Dark orange flames / black tips
Air shutter closed too far
Excessive burner media
Lifting (ghosting) flames
Improper Venting
Gas pressure too high
WARNING:
Servicing of this appliance
must be conducted by a qualified service technician
. Improper servicing, adjustment or
alteration of this appliance may cause property damage, personal injury or loss of life. All servicing should be conducted
with the appliance cold. All replacement parts must be authorized by Archgard for suitability.