20
Installation
12.0 Conversion Kit Instructions
IMPORTANT:
This fireplace is Natural gas ready. If converting to LP gas, follow instructions below.
WARNING:
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturers instructions
and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed
exactly, a fire, explosion or productions of carbon monoxide may result, causing property damage, personal injury or loss of life. The
qualified service agency is responsible for proper installation of this kit. The installation is not proper and complete until operation
of the converted appliance is checked as specified in the instructions supplied with the kit. Refer to appliance owner’s manual or
product data plate for proper inlet and manifold pressure adjustments and orifice sizing.
IMPORTANT:
For high altitude installations above 4500 ft (1372 meters), consult local gas distributor or the authority having
jurisdiction for proper derating methods.
KIT NUMBERS:
22-CKMLP
for LP gas and
22-CKMNG
for Natural Gas
KIT INCLUDES:
•
Gas conversion label (303-0128)
•
Burner orifice (part number 301-6000-54, #54 DMS [1.397 mm] for LPG) (part number 301-6000-44, #44 DMS [2.18 mm] for NG)
•
Instruction Sheet
•
SIT 820 Valve conversion kit c/w instructions & gas type label
WARNING: SHUT OFF GAS SUPPLY AND ELECTRICAL POWER TO FIREPLACE
SHUT OFF GAS SUPPLY BEFORE DISCONNECTING ELECTRICAL POWER
12.1 Prepare the Fireplace
Remove the surround, barrier screen, glass frame assembly, logs or glass media, embers and brick panels or firebox liner (if
applicable)*.
Remove the burner*.
*See relevant sections in this manual.
Remove the burner orifice using a 3/8” wrench. Replace with the orifice supplied with the
conversion kit. Use a small amount of pipe sealant on the threads of the orifice mount. Do not
use too much as it can block the orifice.
Figure 12.1.01:
WARNING: Installation should be carried out in a clean environment.
WARNING: This modulating conversion kit must ONLY be applied as part of a conversion kit supplied by the APPLIANCE
MANUFACTURER.
WARNING: Correct operation of the system cannot be guaranteed if the conversion kit or valve has been dropped or has
sustained a strong impact.
INSTALLER NOTICE: These instructions must be left with appliance.
Figure 12.2.01:
12.2 Pilot Conversion
Using a 7/16” wrench and loosen the pilot hood 1/4 turn.
Slide the tab at the bottom of the orifice hood all the way
so the red side (propane) with the hole in it is showing.
Tighten the pilot hood back up so that it is lined up with
the two probes on both sides of the pilot assembly.