Installation
9.1 Surround Configuration Options
The surround may be adjusted to accommodate a variety of openings and aesthetic preferences.
The following table indicates opening dimensions required for each possible position of the surround. The dimensions indicated in the
images below correspond with the locations shown in
Figure 9.0.01
.
Position 1
Position 2
Position 3
A
B
C
A
B
C
A
B
C
Minimum Depth
Door Flush
Screen Flush
A
B
C
A
B
C
A
B
C
Minimum Depth
Door Flush
Screen Flush
A
B
C
A
B
C
A
B
C
Minimum Depth
Door Flush
Screen Flush
E
F
D
G
E
F
D
G
E
F
D
G
Minimum Depth
Screen Flush
Door Flush
E
F
D
G
E
F
D
G
E
F
D
G
Minimum Depth
Screen Flush
Door Flush
E
F
D
G
E
F
D
G
E
F
D
G
Minimum Depth
Screen Flush
Door Flush
Minimum Depth:
The screen and door both extend
outside of the surround.
Door Flush:
The screen extends outside of the
surround but the face of the door does
not.
Screen Flush:
The face of screen is flush with the
surround.
A
18.0" (45.72 cm)
18.0" (45.72 cm)
18.0" (45.72 cm)
B
12.94" (32.87 cm)
13.41" (34.06 cm)
14.10" (35.81 cm)
C
3.76" (9.55 cm)
4.22" (10.72 cm)
4.91" (12.47 cm)
D
14.17" (35.99 cm)
12.48" (31.70 cm)
12.48" (31.70 cm)
E
16.13" (40.97 cm)
16.62" (42.21 cm)
17.31" (43.97 cm)
F
23.91" (60.73 cm)
25.92" (65.83 cm)
26.48" (67.26 cm)
G
106.75
⁰
112
⁰
112
⁰
Figure 9.1.01:
Caution:
if installing at minimum depth, the rigid black pipe included with this fireplace may impact with the side of some masonry
openings. If so, replace the black pipe provided with a flexible gas line. Follow all local codes.