background image

 
 
 

                               

 
 
 
 
 

 

 

 

 

 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 

Questions about installation, operation, or troubleshooting?

 

 Before returning to your retailer, contact our customer 

service department at 1-877-886-5989, 8:00 a.m.- 4:30p.m., EST, Monday-Friday or e-mail 
[email protected]   

 

ED200T651-0805 

CAUTION 

 FOR YOUR SAFETY

 

 

 

 
 
 
 

 

 

Do not store or use gasoline or other flammable vapors and liquids in vicinity of 
this or any other appliance. 

 

WHAT TO DO IF YOU SMELL GAS 

·

 

Do not try to light any appliance. 

·

 

Do not touch any electrical switch; do not use any phone in your building. 

·

 

Immediately call your gas supplier from a neighbor

s phone. Follow the gas 

supplier

s instructions. 

·

 

If you cannot reach your gas supplier, call the fire department. 

 

   Installation and service must be performed by a qualified installer, service agency 

or the gas supplier. 

INSTALLER: DO NO DISCARD THIS MANUAL 

 LEAVE FOR HOMEOWNER

S FUTURE 

REFERENCE. 

 

WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED 
EXACTLY, A FIRE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL 
INJURY, OR LOSS OF LIFE.

 

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is 
installed. Provisions for adequate combustion and ventilation air must be provided. 
Refer to 

Air For Combustion and Ventilation

 section on page 7 of this manual. 

This appliance may be installed in an aftermarket*, permanently located manufactured 
(mobile) home, where not prohibited by local codes. This appliance is only for use with 
the type of gas indicated on the rating plate. this appliance is not convertible for use 
with other gases. 

 

WARNING:  

This appliance is 

equipped for (Natural and 
Propane) gas. Field conversion is 
not permitted other than between 
natural or propane gases. 

VENT-FREE FIREPLACE 

MODEL: EDP200T-O 
               EDP200T-C 
               EDS200T-HC 

Summary of Contents for EDP200T-C

Page 1: ...cy or the gas supplier INSTALLER DO NO DISCARD THIS MANUAL LEAVE FOR HOMEOWNER S FUTURE REFERENCE WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY A FIRE MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be prov...

Page 2: ...void the warranty PRODUCT SPECIFICATIONS MODEL EDP200T C EDP200T O EDS200T HC Input Rating 20 000 BTU Hr 19 000 BTU Hr 20 000 BTU Hr 19 000 BTU Hr Gas Type Natural LP Propane Natural LP Propane Ignition Electronic Piezo Electronic Piezo Electronic Piezo Electronic Piezo Manifold Pressure 4 in W C 9 in W C 4 in W C 9 in W C Inlet Gas Pressure For purposes of input adjustment Maximum 10 5 in 14 in 1...

Page 3: ...e It is your guide to safe and proper operation of this heater Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this heater WARNING Any change to this fireplace or its controls can be dangerous WARNING Do not allow fans to blow directly into the heater Avoid any drafts that alter burner flame patterns including ceilin...

Page 4: ...bustion and Ventilation pages 7 through 9 If heater keeps shutting off see Troubleshooting pages 19 through 21 10 Do not run heater Where flammable liquids or vapors are used or stored Under dusty conditions 11 Do not use this heater to cook food or burn paper or other objects 12 Do not use this heater if any part has been under water Immediately call a qualified service technician to inspect the ...

Page 5: ...husetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit In the State of Massachusetts unvented propane or natural gas fired space heaters shall be prohibited in bedrooms and bathrooms LOCAL CODES...

Page 6: ...s approximately one 1 ounce 30ml of water for every 1 000 BTU s 3KW s of gas input per hour Unvented room heaters are recommended as a supplemental heater for a room rather than a primary heat source for an entire house In most supplemental heat applications the water vapor does not create a problem In most applications the water vapor enhances the low humidity atmosphere experienced during cold w...

Page 7: ...y if there are doorless passageways or ventilation grills between them Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is defined as construction where a walls and ceilings exposed to the outside...

Page 8: ... an adjoining room If the extra space provides an unconfined space remove door to adjoining room or add ventilation grills between rooms See Ventilation Air from Outdoors page 9 b Vent room directly to the outdoors See Ventilation Air from Outdoors page 9 c Install a lower BTU hr heater if lower BTU hr size makes room unconfined If the actual Btu Hr used is less than the maximum Btu Hr the space c...

Page 9: ...eater in a bedroom or bathroom in a recreational vehicle where curtains furniture clothing or other flammable objects are less than 42 inches from the front top or sides of the heater in high traffic areas in windy or drafty areas CAUTION This heater creates warm air currents These currents move heat to wall surfaces next to heater Installing heater next to vinyl or cloth wall coverings or operati...

Page 10: ...r must be installed INSTALLATION ITEMS NEEDED Before installing heater make sure you have the items listed below piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge connection sediment trap tee joint pipe wrench Flexible Gas hose check local code A CSA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge co...

Page 11: ... shutoff valve in an accessible location The equipment shutoff valve is for turning on or shutting off the gas to the appliance Apply pipe joint sealant lightly to male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves CAUTION Use pipe joint sealant that is resistant to gas PROPANE or NG We recommend that you install a sedime...

Page 12: ...gure 9 Selection valve must be locked into either the NG position Do not operate heater between locked positions 3 Rotate and close cover over gas selection valve and reinstall screw 4 Remove hex plug with wrench provided from natural gas inlet of regulator and install into LP inlet of regulator use thread sealant to assure there are no leaks For changing from natural gas supply to propane gas sup...

Page 13: ... Bubbles forming show a leak Correct all leaks immediately Pressure Testing Heater Gas Connections 1 Open equipment shutoff valve see Figure 11 2 Open gas supply tank valve 3 Make sure control knob of heater is in the OFF position 4 Check all joints from equipment shutoff valve to control valve Figure 11 Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 5 Correct all...

Page 14: ... so reposition logs according to the log installation instructions in this manual Flames contacting logs will create soot IMPORTANT Make sure log does not cover any burner ports see Figure 13 It is very important to install the logs exactly as instructed Do not modify logs Only use logs supplied with the heater Figure 13 Installing Log Set All logs STEP 1 Install log 1 onto the two slots in the re...

Page 15: ...n your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in control knob Never use tools If the appliance could not operate do not try to repair it Call a qualified service technician or gas supplier Forced or attempted re pair may result in a fire or...

Page 16: ...ater and near floor If you smell gas STOP Follow B in the safety information on Warnings plate If you don t smell gas go to the next step 7 Turn control knob counterclockwise to the PILOT position Keep control knob pressed in for five 5 seconds Note You may be running this heater for the first time after hooking up to gas supply If so the control knob may need to be pressed in for 30 seconds This ...

Page 17: ... The incorrect pilot flame is not touching the thermocouple This will cause the thermocouple to cool When the thermocouple cools the heater will shut down If the pilot flame is incorrect as shown in Figure16 Turn heater off see To Turn Off Gas to Appliance page 16 See troubleshooting page 19 21 BURNER FLAME PATTERN Figure 17 shows a correct burner flame pattern Figure 18 shows an incorrect burner ...

Page 18: ...r through the ports slots and holes in the burner 4 Check the injector holder located at the end of the burner tube again Remove any large particles of dust dirt lint or pet hair with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air holes on the injector holder see Figure19 6 In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4 Clean the p...

Page 19: ... broken 3 Ignitor electrode is not connected to ignitor cable 4 Ignitor cable is pinched 5 Damaged ignitor cable 6 Bad piezo ignitor 7 Low battery 1 Replace ignitor 2 Replace electrode 3 Reconnect ignitor cable 4 Free ignitor cable if pinched by any metal or tubing 5 Replace ignitor cable 6 Replace piezo ignitor 7 Replace battery When ignitor button is pressed in there is a spark at ODS pilot but ...

Page 20: ...intenance Page 18 replace 2 Contact Dealer or Customer Service 3 Replace gas regulator High yellow flame during burner combustion 1 Gas selection valve not set correctly 2 Dirty or clogged burner 3 Not enough air 4 Gas regulator is defective 5 Inlet gas pressure is too low 1 Make sure gas selection valve is set properly 2 Check burner for dirt and debris If found clean burner see Cleaning and Main...

Page 21: ...ile pressing ignitor button 3 Air in gas lines when installed 4 ODS pilot is clogged 5 Gas regulator setting is not correct 6 Bad piezo ignitor 7 Depleted gas supply 1 Turn on gas supply of open equipment shutoff valve 2 Fully press in control knob while pressing ignitor button 3 Continue holding down control knob Repeat igniting operation until air is moved 4 Clean ODS pilot see Cleaning and Main...

Page 22: ...Service or your dealer have ready Your name Your address Model and serial number of your heater How heater was malfunctioning Type of gas used Propane LP or Natural gas NG Purchase date Usually we will ask you to return the defective part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call Customer Service toll fr...

Page 23: ...ART NUMBER DESCRIPTION QTY 1 ED200T230 Burner Assembly 1 2 NDD0308 DF ODS 1 3 SIT545 200 T Stat Valve 1 4 AL092 01 Piezo Ignitor 1 5 RV83FI 4 9 DF Regulator 1 6 YDF06 Gas Selection Valve 1 7 ED200T209 Main Outlet Tube Assembly 1 8 ED200T208 Main Inlet Tube Assembly 1 9 ED200T210 ODS Pilot Gas Tube Assembly 1 10 ED200T211 ODS Outlet Tube Assembly LP 1 11 ED200T212 ODS Outlet Tube Assembly NG 1 23 ...

Page 24: ...0L14 02 C Panel 1 13 ED200L14 04 O Decorative Column Caps 4 14 ED200L14 04 C Decorative Column Caps 4 15 ED200T002 Top Panel 1 1 16 ED200T001 Body Boarding 1 1 17 ED200T003 Bottom Panel 1 1 18 ED200T040 Firebox Assembly 1 1 19 EL010 01C 01 Top Decorative Panel 1 1 20 EL002 01A 01 Upper Louver 1 1 21 EL003 01A 01 Mid Louver 1 1 22 ED200T201 Burner Pan 1 1 23 EL012 06B 01 Lower Front Panel Right 1 1...

Page 25: ...EDP200T O EDP200T C 25 ...

Page 26: ...00T001 Body Boarding 1 8 ED200T003 Bottom Panel 1 9 ED200T040 Firebox Assembly 1 10 EL010 01C 01 Top Decorative Panel 1 11 EL002 01A 01 Upper Louver 1 12 EL003 01A 01 Mid Louver 1 13 ED200T201 Burner Pan 1 14 EL012 06B 01 Lower Front Panel Right 1 15 EL012 06A 01 Lower Front Panel Left 1 16 ED200T005 Control Panel 1 17 EB29600H Grill Assembly 1 18 EL013 01B1 01 Door 1 19 EL010 01B 01 Right Decorat...

Reviews: