4.5 File Conversion on Convert Screen
4-57
Figure 4.5.4-9 Bandwidth Dialog Box
■
Selecting spectrum (available for ASCII1, ASCII2, ASCII3, and Digitizer)
Click the
button on the right of the Spectrum box to open a
pull-down menu, and select the spectrum from Normal and Reverse.
When Reverse is selected, the phase of the RF modulated signal output is
reversed.
Figure 4.5.4-10 Spectrum Dialog Box
■
Setting over sampling rate (available for ASCII1, ASCII2, ASCII3, and
Digitizer when in MG3710/MG3740 mode)
Set the over sampling rate for the waveform pattern to be input to
Convert. Click the Over Sampling box and enter a numeric value. For
example, to specify a sampling rate of 4 MHz for signals that have a
1-MHz symbol rate, enter “4”.
Figure 4.5.4-11 Over Sampling Dialog Box
■
Setting Data Points (available for ASCII1, ASCII2, and ASCII3)
The number of sample points of the read waveform pattern is displayed
in the Data Points box. Usually, this setting is not required to be changed.
In case of change, enter the value into the Data Points dialog box.
Figure 4.5.4-12 Data Points Dialog Box
When the number of sample points of the read waveform is less than
1000 points, the output pattern is repeated so that the number of output
patterns becomes 1000 points or more. When the number of sample
points of the read waveform is 99 points, for example, the output pattern
is repeated 11 times and a waveform pattern with 1089 points is output.