User Manual
EC1000S
California Instruments
177
The same setting range limit is used for all output modes. Not only the currently selected output mode
setting, but the settings for all other modes are restricted by this limit. (The EC1000S stores the setting for
each output mode.)
The following describes an example where the selected output mode is AC-INT and the limit is set to
prevent the output voltage from exceeding 100.0 Vrms.
In this case, the output limit range must be set to ±141.4 V (100.0 Vrms), but this setting cannot be made
unless the output voltage setting is 100.0 Vrms or less for the other output modes where the output voltage
can be set, i.e., the AC-ADD, AC-SYNC, AC+DC-INT, AC+DC-ADD, and AC+DC-SYNC modes. If the
setting for AC-ADD is 110.0 Vrms, the setting range limit cannot be set within ±155.5 V (110.0 Vrms), even
if the setting for the selected AC-INT is 100.0 Vrms.
Memory and sequences are not subject to setting range limits.
5.5.6 Selection of measurement display (MEASURE)
Select the measured values to be displayed, from the RMS value (RMS), average DC (AVG), peak value
(PEAK), and harmonic current values (HC1 to HC4).
When harmonic current value is selected, the RMS value, average DC, and peak value are not measured.
When measurement of the RMS value, average DC, or peak value has been set, harmonic current is not
measured.
S
ee “3.4.9 Using measurement functions”
, for description of measurement display selection.
S
ee “4.3 Measurement of Harmonic Current”
and
“5.4.6 Output harmonic current measurement”
, for description of harmonic current measurement.
5.5.7 Reset of peak current hold value
This resets the peak current hold value.
A reset sets the peak current hold value to 0 Apk, and then holds the new peak value.
S
ee “4.2.4 Reset the peak current hold value”
, for description of resetting peak current hold value.
5.5.8 Output on/off
The EC1000S output on/off setting can be entered using the
OUTPUT
key on the front panel, but it can also be
controlled via the MISC menu.
.
Содержание EC1000S
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 6: ...ii This page intentionally left blank...
Страница 10: ...User Manual EC1000S 6 9 SPECIFICATIONS Lists the specifications functions and performance of the EC1000S...
Страница 18: ...User Manual EC1000S Contents California Instruments 14 9 17 External Dimensions and Weight 286...
Страница 24: ......
Страница 32: ...User Manual EC1000S California Instruments 28...
Страница 41: ...User Manual EC1000S California Instruments 37 The product itself has a withstand voltage of 1500 V AC...
Страница 46: ......
Страница 145: ...User Manual EC1000S California Instruments 141 ENTER CANCEL...
Страница 146: ......
Страница 194: ......
Страница 217: ...User Manual EC1000S California Instruments 213 Response example 200 0...
Страница 248: ......
Страница 266: ......
Страница 274: ......