User Manual
EC1000S
California Instruments
249
7.2.1 Error at power-on
The EC1000S performs the following fault checks at power-on.
If an error occurs, NG is displayed on the system check screen. Nothing is displayed when all check
items are OK.
ROM CHECK...................... OK
RAM READ/WRITE CHECK ........... OK
BACKUP MEMORY CHECK ............ OK
WAVE MEMORY CHECK .............. OK
SEQUENCE MEMORY CHECK .......... OK
CALIBRATION MEMORY CHECK ...... NG .... INITIALIZED
VERSION CHECK .................. NG .... INITIALIZED
Figure 7-1. Screen Display When Self Fault Check Errors Have Occurred
lists check items and processing when a fault is detected.
Table 7-2. Self Fault Check Messages
Message
Fault Check Item
Cause and Operation or Action Required
When Fault Is Detected
ROM CHECK
ROM sum check
Message is displayed and the system will not
start.
The cause may be a faulty component.
Contact California Instruments or its
representative.
RAM READ/WRITE
CHECK
RAM read/write check
BACKUP MEMORY
CHECK
Backup memory sum
check
Target memory is initialized, then the system
is started.
(
See “3.2
Display and Initial Settings at
.)
If this occurs frequently, it may be due to
deterioration of the backup battery.
(
See “8.5
.)
WAVE MEMORY
CHECK
Waveform memory sum
check
SEQUENCE
MEMORY CHECK
Sequence memory sum
check
CALIBRATION
MEMORY CHECK
Calibration data check
The calibration value memory is initialized,
then the system is started.
In this case, the EC1000S is started without
calibrated values, so it may not provide the
expected performance. Also, this may be due
to a faulty component, in which case California
Содержание EC1000S
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 6: ...ii This page intentionally left blank...
Страница 10: ...User Manual EC1000S 6 9 SPECIFICATIONS Lists the specifications functions and performance of the EC1000S...
Страница 18: ...User Manual EC1000S Contents California Instruments 14 9 17 External Dimensions and Weight 286...
Страница 24: ......
Страница 32: ...User Manual EC1000S California Instruments 28...
Страница 41: ...User Manual EC1000S California Instruments 37 The product itself has a withstand voltage of 1500 V AC...
Страница 46: ......
Страница 145: ...User Manual EC1000S California Instruments 141 ENTER CANCEL...
Страница 146: ......
Страница 194: ......
Страница 217: ...User Manual EC1000S California Instruments 213 Response example 200 0...
Страница 248: ......
Страница 266: ......
Страница 274: ......