User Manual
EC1000S
California Instruments
214
[SOURce:]VOLTage:LIMit:LOW
This sets the upper limit of the output voltage that can be set. However, a value that is at or
below the currently set cannot be specified. ([5,
“Out of Limiter”] error occurs.)
For the 100 V range, the limit value setting ranges from
200.0 to
5.0 V, and for the 200 V
range, it ranges from
400.0 to
10.0 V.
Syntax:
[SOURce:]VOLTage:LIMit:LOW <NR2>
Parameters:
200.0 to
5.0 (
400.0 to
10.0)
Command example: VOLT:LIM:LOW
200
Query example:
VOLT:LIM:LOW?
Response format:
<NR2>
Response example:
200.0
[SOURce:]VOLTage:OFFSet[:IMMediate]
This sets the DC voltage when in AC+DC-INT, AC+DC-ADD, or AC+DC-SYNC mode. For the
100 V range, the DC output voltage setting ranges from
200.0 to 200.0 V, and for the 200 V
range, it range, from
400.0 to 400.0 V.
The DC output voltage cannot be set unless the mode is AC+DC-INT, AC+DC-ADD, or
AC+DC-SYNC mode. ([3,
“Invalid in this mode”] error occurs.)
Syntax:
[SOURce:]VOLTage:OFFSet[:IMMediate] <NR2>
Parameters:
200.0 to 200.0 (
400.0 to 400.0)
Command example: VOLT:OFFS 10
Query example:
VOLT:OFFS?
Response format:
<NR2>
Response example:
10.0
[SOURce:]VOLTage:RANGe
This sets the output voltage range. The output voltage range setting is 100 V or 200 V.
However, when output is on, output voltage range cannot be changed. ([1,
“Invalid with output
on
”] error occurs.)
Syntax:
[SOURce:]VOLTage:RANGe <NR1>
Parameters:
100/200
Command example: VOLT:RANG 100
Query example:
VOLT:RANG?
Response format:
<NR1>
Response example:
100
Содержание EC1000S
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 6: ...ii This page intentionally left blank...
Страница 10: ...User Manual EC1000S 6 9 SPECIFICATIONS Lists the specifications functions and performance of the EC1000S...
Страница 18: ...User Manual EC1000S Contents California Instruments 14 9 17 External Dimensions and Weight 286...
Страница 24: ......
Страница 32: ...User Manual EC1000S California Instruments 28...
Страница 41: ...User Manual EC1000S California Instruments 37 The product itself has a withstand voltage of 1500 V AC...
Страница 46: ......
Страница 145: ...User Manual EC1000S California Instruments 141 ENTER CANCEL...
Страница 146: ......
Страница 194: ......
Страница 217: ...User Manual EC1000S California Instruments 213 Response example 200 0...
Страница 248: ......
Страница 266: ......
Страница 274: ......