User Manual
EC1000S
California Instruments
105
Step 1
Step 2
Step 5
Output parameter
Step 2 settings
• Final value
• Step time
• Branch step 5
Time
Step 5 settings
• Final value from previous step is used
<Branch>
Figure 4-8. Example of Sequence Operation at <Branch>
e)
Sequence loop
Either an entire sequence or a block of any number of steps within a sequence can be used as a
sequence loop. The loop is implemented based on the [jump step] and [jump times] parameters
specified for each step. The jump counter, which counts the number of jumps, functions within each
step to retain a count, so multiple loops can be implemented.
below illustrates the loop specification method and the step transitions.