Parameters:
<Boolean>
Enables (ON) or disables (OFF) the source power calibration for
port number
<PhyPt>
.
*RST:
OFF
Example:
See
SOURce<Ch>:POWer:CORRection[:ACQuire]
Manual operation:
See
7.3.15.6
SOURce:POWer... (other)
The
SOURce:POWer...
commands define the power of the internal signal source.
SOURce<Ch>:POWer<PhyPt>:CORRection:LEVel:OFFSet
............................................. 1038
SOURce<Ch>:POWer<PhyPt>[:LEVel][:IMMediate][:AMPLitude]
...................................... 1039
SOURce<Ch>:POWer<PhyPt>[:LEVel][:IMMediate]:OFFSet
............................................ 1040
SOURce<Ch>:POWer<PhyPt>[:LEVel][:IMMediate]:SLOPe
............................................. 1040
................................................................................ 1041
SOURce<Ch>:POWer<PhyPt>:REDuce[:STATe]
.............................................................1041
............................................................................1042
........................................................................... 1042
............................................................................ 1042
.............................................................................. 1043
............................................................................1043
SOURce<Ch>:POWer<PhyPt>:CORRection:LEVel:OFFSet
<Offset>
Specifies a gain (positive values) or an attenuation (negative values) in the signal path
between the source port and the calibrated reference plane. The value has no impact
on the source power.
Suffix:
<Ch>
.
Calibrated channel number
<PhyPt>
Calibrated port number
Parameters:
<Offset>
Gain or attenuation value
Range:
-300 dB to +300 dB (adjust to the test setup)
Increment: 0.01 dB (other values are rounded)
*RST:
0 dB
Default unit: dB