88
Rockwell Automation Publication 1783-UM007I-EN-P - December 2017
Chapter 3
Configure Switch Features
Clock Quality
Displays a summary of the quality of the Grandmaster clock:
•
Class—Time and frequency traceability of the Grandmaster clock.
•
Accuracy—Expected accuracy of the Grandmaster clock when the Best Master Clock algorithm is in use.
•
Offset (log variance)— Offset between the local clock and an ideal reference clock.
Steps Removed
Displays the number of hops from the local clock to the Grandmaster clock.
Local clock time
Displays the time stamp of the local clock.
PTP Time Property
Current UTC offset valid
Indicates whether the current Coordinated Universal Time (UTC) offset is valid.
Current UTC offset
Displays the offset between the International Atomic Time (TAI) and UTC in seconds.
Time Source
Displays the time source used by the Grandmaster clock.
Time Property Persistence
Displays the number of seconds that time properties are preserved after a primary Grandmaster clock fails and a secondary Grandmaster clock
takes over.
Device Clock Details
Device Time Source
Displays the time source used by the switch.
Device Clock Time
Displays the time on the switch, obtained from the time source.
Per Port Settings
Port Name
Displays the port type and port number:
•
Fa—Fast Ethernet
•
Gi—Gigabit Ethernet
•
Te—10 Gigabit Ethernet
State
Displays the synchronization state of the switch port with the parent or Grandmaster clock:
•
Initializing—The switch port is waiting while a parent or Grandmaster clock is selected.
•
Listening—The switch port is waiting while a parent or Grandmaster clock is selected.
•
Pre-master—The switch port is transitioning to change to Master state.
•
Master—The switch is acting as a parent clock to the devices connected to that switch port.
•
Passive—The switch has detected a redundant path to a parent or Grandmaster clock. For example, two different switch ports claim the same
parent or Grandmaster clock. To help prevent a loop in the network, one of the ports changes to Passive state.
•
Uncalibrated—The switch port cannot synchronize with the parent or Grandmaster clock.
•
Slave—The switch port is connected to and synchronizing with the parent or Grandmaster clock.
•
Faulty—Either PTP is not operating properly on the switch port or nothing is connected to the port.
•
Disabled—PTP is not enabled on the switch port.
Enable
Check the checkbox for each port on which to enable PTP. You can enable one or more switch ports.
By default, PTP is enabled on all the Fast Ethernet and Gigabit Ethernet ports.
For Stratix 8000/8300 switches, only the ports on the base switch module are PTP-capable. The switch expansion modules do not support PTP.
When at least one switch port is PTP-enabled, the End to End Transparent mode is selected by default.
Delay Request Interval
The logarithmic mean interval in seconds
Type the recommended to connected devices to send delay request messages when the switch port is in the master state.
Valid values:
•
-1—half second
•
0—1 second
•
1—2 seconds
•
2—4 seconds
•
3—8 seconds
•
4—16 seconds
•
5—32 seconds
•
6—64 seconds
Default: 5 (32 seconds)
Announce Timeout
Type the number of announce intervals, specified as the logarithmic mean in seconds, that must pass without receipt of an announce message
from the parent or Grandmaster clock before the switch selects a new parent or Grandmaster clock.
Valid values: 2…10
Default: 3 (8 seconds)
Table 28 - Boundary Mode Fields (Continued)
Field
Description
Содержание armorstratix 5700
Страница 10: ...10 Rockwell Automation Publication 1783 UM007I EN P December 2017 Table of Contents Notes ...
Страница 12: ...12 Rockwell Automation Publication 1783 UM007I EN P December 2017 Preface Notes ...
Страница 72: ...72 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 2 Get Started Notes ...
Страница 148: ...148 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 3 Configure Switch Features ...
Страница 282: ...282 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 3 Configure Switch Features Notes ...
Страница 317: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 317 Monitor the Switch Chapter 4 ...
Страница 319: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 319 Monitor the Switch Chapter 4 ...
Страница 325: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 325 Monitor the Switch Chapter 4 ...
Страница 338: ...338 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 5 Troubleshoot the Switch Notes ...
Страница 396: ...396 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix A DataTypes Notes ...
Страница 404: ...404 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix B Port Assignments for CIP Data Notes ...
Страница 450: ...450 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix D Cables and Connectors Notes ...
Страница 457: ......