434
Rockwell Automation Publication 1783-UM007I-EN-P - December 2017
Appendix D
Cables and Connectors
Connect to 10BASE-T- and 100BASE-TX-Compatible Devices
The auto-MDIX feature is enabled by default. Follow these cabling guidelines
when the auto-MDIX feature has been disabled.
When connecting the ports to 10BASE-T- and 100BASE-TX-compatible
devices, such as servers and routers, you can use a two or four twisted-pair,
straight-through cable that is wired for 10BASE-T and 100BASE-TX.
To identify a crossover cable, compare the two modular ends of the cable. Hold
the cable ends side-by-side, with the tab at the back. The color of the wire that
is connected to the pin on the outside of the left plug must differ in color from
the wire that is connected to the pin on the inside of the right plug.
and
show the cable schematics.
Figure 66 - Two Twisted-pair Straight-through Cable Schematics
Figure 67 - Four Twisted-pair Straight-through Cable Schematics
When connecting the ports to 10BASE-T- and 100BASE-TX-compatible
devices, such as switches or repeaters, you can use a two or four twisted-pair,
crossover cable.
Use a straight-through cable to connect two ports when only one port is
designated with an X. Use a crossover cable to connect two ports when both
ports are designated with an X or when both ports do not have an X.
Switch
3 TD+
6 TD–
1 RD+
2 RD–
Router or Personal Computer
3 RD+
6 RD–
1 TD+
2 TD–
1 TPO+
2 TPO-
3 TP1+
6 TP1-
1 TP1+
Switch
Router or Personal Computer
2 TP1-
3 TPO+
6 TPO-
4 TP2+
5 TP2-
7 TP3+
8 TP3-
4 TP3+
5 TP3-
7 TP2+
8 TP2-
Содержание armorstratix 5700
Страница 10: ...10 Rockwell Automation Publication 1783 UM007I EN P December 2017 Table of Contents Notes ...
Страница 12: ...12 Rockwell Automation Publication 1783 UM007I EN P December 2017 Preface Notes ...
Страница 72: ...72 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 2 Get Started Notes ...
Страница 148: ...148 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 3 Configure Switch Features ...
Страница 282: ...282 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 3 Configure Switch Features Notes ...
Страница 317: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 317 Monitor the Switch Chapter 4 ...
Страница 319: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 319 Monitor the Switch Chapter 4 ...
Страница 325: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 325 Monitor the Switch Chapter 4 ...
Страница 338: ...338 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 5 Troubleshoot the Switch Notes ...
Страница 396: ...396 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix A DataTypes Notes ...
Страница 404: ...404 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix B Port Assignments for CIP Data Notes ...
Страница 450: ...450 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix D Cables and Connectors Notes ...
Страница 457: ......