Rockwell Automation Publication 1783-UM007I-EN-P - December 2017
293
Monitor the Switch
Chapter 4
Table 105 - Stratix 5410 System Status Indicators
Indicator
Status
Description
EIP Mod
The EIP Mod status indicator shows the status of the switch.
Off
Power to the switch is off or is not properly connected.
Solid green
The switch is operating properly.
Flashing green
The switch is not configured. For example, the switch does not have an IP address configured.
Flashing red
The switch has detected a recoverable system fault.
Solid red
The switch has detected a nonrecoverable system fault.
Flashing green and red
The switch is running its power-on self-test (POST).
EIP Net
The EIP Net status indicator shows the network status of the switch.
Off
Power to the switch is off or is not properly connected.
Solid green
The switch has an established CIP connection to one or more attached devices.
Flashing green
The switch has an IP address but the switch does not have an established connection to one or more attached devices.
Flashing red
One or more connections to attached devices have timed out.
Solid Red
The switch has detected that its IP address is already in use by another device in the network.
Flashing green and red
The switch is running its power-on self-test (POST).
Setup
The Setup status indicator shows the status of the initial setup of the switch.
The behavior of the Setup status indicator varies depending on whether you run single-mode or multi-mode Express Setup. In multi-mode Express Setup, the
behavior varies based on whether you run Short Press, Medium Press, or Long Press mode. For details about the Setup status indicator behavior during Express
Setup, refer to
,
GPS
Supported only on Stratix 5410 series B switches with IOS Release 15.2(6)E0a and later. Indicates the status of the global navigation satellite system (GNSS).
Off
GNSS is not operational.
Solid green
•
GNSS is in a normal state and Self-survey mode is complete.
•
GNSS has a valid signal.
Flashing green
•
GNSS is in Self-survey mode.
•
The signal is lost.
Solid amber
•
GNSS receiver firmware update is in process. After the GNSS receiver firmware update is complete, GNSS is reset and the status
indicator flashes green as the self-survey process starts after reset.
•
A GNSS error occurred, such as antenna open, antenna shorted, or no tracking satellite.
TimeCD
Not available in the current release.
Alarms 1…4
The alarm input status indicators show the status of the alarm inputs.
Off
Alarm input is not configured.
Solid green
Alarm input is configured; no alarm is detected.
Solid red
Minor alarm is detected.
Flashing red
Major alarm is detected.
Alternating green and
red
Critical alarm is detected.
Alarm Out
The alarm input status indicator shows the status of the alarm output.
Off
Alarm Out is not configured.
Solid green
Alarm Out is configured; no alarm is detected.
Solid red
Alarm is detected.
PSU 1
PSU 2
The power status indicators show the status of power to the switch.
Содержание armorstratix 5700
Страница 10: ...10 Rockwell Automation Publication 1783 UM007I EN P December 2017 Table of Contents Notes ...
Страница 12: ...12 Rockwell Automation Publication 1783 UM007I EN P December 2017 Preface Notes ...
Страница 72: ...72 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 2 Get Started Notes ...
Страница 148: ...148 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 3 Configure Switch Features ...
Страница 282: ...282 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 3 Configure Switch Features Notes ...
Страница 317: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 317 Monitor the Switch Chapter 4 ...
Страница 319: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 319 Monitor the Switch Chapter 4 ...
Страница 325: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 325 Monitor the Switch Chapter 4 ...
Страница 338: ...338 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 5 Troubleshoot the Switch Notes ...
Страница 396: ...396 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix A DataTypes Notes ...
Страница 404: ...404 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix B Port Assignments for CIP Data Notes ...
Страница 450: ...450 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix D Cables and Connectors Notes ...
Страница 457: ......