Rockwell Automation Publication 1783-UM007I-EN-P - December 2017
231
Configure Switch Features
Chapter 3
Figure 33 - Port Thresholds for Stratix 8000/8300 Switches
Table 89 - Port Threshold Fields for Stratix 8000/8300 Switches
Field
Description
Unit
Indicates where the port resides:
•
Base (for example, 1783-MS10T)
•
Expansion module (for example, 1783-MX08T)
Port
Indicates the port that is selected for configuration.
The port number includes the port type (Fa for Fast Ethernet and Gi for Gigabit Ethernet), the base or expansion module
number (1, 2, or 3), and the specific port number. For example:
•
Gi1/1 is Gigabit Ethernet port 1 on the base.
•
Fa2/1 is Fast Ethernet port 1 on the first expansion module.
Storm Control Threshold Settings
Set the threshold values for the broadcast, unicast, and multicast traffic for each port. The number of packets being sent is
compared against the threshold value. If an undesirable network event occurs and the threshold value has been exceeded, a
Yes value appears on the Port Status view and in the Traffic Threshold Exceeded on Any Port field on the Switch Status view.
Network traffic of the type that exceeded threshold (broadcast, unicast, or multicast) is dropped until it falls below the falling
threshold. The falling threshold is automatically set to 5% less than the entered threshold value.
Broadcast, Unicast and Multicast
Complete these fields for each traffic type:
•
Enable—Check to enable the storm control on the selected port. The respective threshold value and units are applied to
the selected port when you click Set. Clear the checkbox to disable the storm control for the selected port. Zero is applied
to the threshold value and units attributes when you click Set.
•
Threshold—Type the value for the threshold after you choose the unit of measurement:
–
If Units is set to pps or bps, type a value between 0…10000000000.
–
If Units is set to %, type a value between 0…100.
•
Units—Choose the unit of measurement for the threshold:
–
pps (packets per second)
–
bps (bits per second)
–
%
Содержание armorstratix 5700
Страница 10: ...10 Rockwell Automation Publication 1783 UM007I EN P December 2017 Table of Contents Notes ...
Страница 12: ...12 Rockwell Automation Publication 1783 UM007I EN P December 2017 Preface Notes ...
Страница 72: ...72 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 2 Get Started Notes ...
Страница 148: ...148 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 3 Configure Switch Features ...
Страница 282: ...282 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 3 Configure Switch Features Notes ...
Страница 317: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 317 Monitor the Switch Chapter 4 ...
Страница 319: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 319 Monitor the Switch Chapter 4 ...
Страница 325: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 325 Monitor the Switch Chapter 4 ...
Страница 338: ...338 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 5 Troubleshoot the Switch Notes ...
Страница 396: ...396 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix A DataTypes Notes ...
Страница 404: ...404 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix B Port Assignments for CIP Data Notes ...
Страница 450: ...450 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix D Cables and Connectors Notes ...
Страница 457: ......