288
Rockwell Automation Publication 1783-UM007I-EN-P - December 2017
Chapter 4
Monitor the Switch
Table 102 - Stratix 5700 and ArmorStratix 5700 Port Status Indicators
Mode
Status
Description
Status
In Status mode, the port status indicators show the connection and activity status of the port. Status mode is the default mode.
Off
No link is present on the port.
Solid green
Port link; no activity.
Flashing green and off
Link is active and healthy.
Alternating green and
amber
There is a fault or error on the link.
Solid amber
The port is disabled.
Duplex
In Duplex mode, the port status indicators show the Duplex mode (Full-duplex or Half-duplex) of the ports. The 10/100/1000 ports operate only in Full-duplex
mode.
Off
The port is not operating.
Solid amber
The port is operating in Half-duplex mode.
Solid green
The port is operating in Full-duplex mode.
Speed
In Speed mode, the port status indicators show the operating speed of the ports.
Off
The port is not operating.
Solid amber
The port is operating at 10 Mbps.
Solid green
The port is operating at 100 Mbps.
Flashing green
The port is operating at 1000 Mbps.
Power
In Power mode, the port status indicators show the status of PoE on switch models with PoE capability.
Off
PoE is disabled on the port.
Solid green
PoE is enabled on the port. The switch port is providing power.
Flashing green and
amber
PoE is denied because it exceeds the power capacity of the switch.
Flashing amber
PoE is denied because it exceeds the configured power limit for the switch port.
Содержание armorstratix 5700
Страница 10: ...10 Rockwell Automation Publication 1783 UM007I EN P December 2017 Table of Contents Notes ...
Страница 12: ...12 Rockwell Automation Publication 1783 UM007I EN P December 2017 Preface Notes ...
Страница 72: ...72 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 2 Get Started Notes ...
Страница 148: ...148 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 3 Configure Switch Features ...
Страница 282: ...282 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 3 Configure Switch Features Notes ...
Страница 317: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 317 Monitor the Switch Chapter 4 ...
Страница 319: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 319 Monitor the Switch Chapter 4 ...
Страница 325: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 325 Monitor the Switch Chapter 4 ...
Страница 338: ...338 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 5 Troubleshoot the Switch Notes ...
Страница 396: ...396 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix A DataTypes Notes ...
Страница 404: ...404 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix B Port Assignments for CIP Data Notes ...
Страница 450: ...450 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix D Cables and Connectors Notes ...
Страница 457: ......