Configure Switch Features
Chapter 3
Table 71 - Single Translation
Field
Description
Type of Entry
Choose Single. Single is the default value.
Starting Public IP Address
Type the existing address for the device on the public subnet.
Starting Private IP Address
Type a unique private address to represent the device.
Effective Public Addresses
Displays the existing address for the device on the public subnet that is configured for translation.
If blank, verify that the values in the preceding fields are valid.
Effective Private Addresses
Displays the unique private address to represent the device.
If blank, verify that the values in the preceding fields are valid.
Table 72 - Range Translation
Field
Description
Type of Entry
Choose Range.
Starting Public IP Address
Type the existing starting address for the device on the public subnet.
Starting Private IP Address
Type a unique, starting private address to represent the devices.
Range
Type the number of addresses to include in the range.
Valid values: 2…128
Default value = 1
IMPORTANT:
Each address in the range counts as one translation entry. The switch supports a maximum of 128 translation entries.
Effective Public Addresses
Displays the range of existing addresses for devices on the public subnet that are configured for translation.
If blank, verify that the values in the preceding fields are valid.
Effective Private Addresses
Displays the range of unique private addresses to represent the devices.
If blank, verify that the values in the preceding fields are valid.
Table 73 - Subnet Translation
Field
Description
Type of Entry
Choose Subnet.
Starting Public IP Address
Type the existing starting address for a device on the public subnet. This address must correspond to the size of the subnet mask to translate.
Subnet Mask
Starting Public Subnet Address
255.255.0.0
The last two octets must end in 0.
EXAMPLE:
10.200.0.0
255.255.255.0
The last octet must end in 0.
EXAMPLE:
10.200.1.0
255.255.255.128
The last octet must end in 0 or 128.
EXAMPLE:
10.200.1.0 or 10.200.1.128
255.255.255.192
The last octet must end in one of the following: 0, 64, 128, 192.
EXAMPLE:
10.200.1.64
255.255.255.224
The last octet must end in one of the following: 0, 32, 64, 96, 128, 160, 192, 224.
EXAMPLE:
10.200.1.32
255.255.255.240
The last octet must end in one of the following: 0, 16, 32, 48, 64, 80, 96, 112, 128, 144, 160, 176, 192,
208, 224, 240.
EXAMPLE:
10.200.1.16
Содержание armorstratix 5700
Страница 10: ...10 Rockwell Automation Publication 1783 UM007I EN P December 2017 Table of Contents Notes ...
Страница 12: ...12 Rockwell Automation Publication 1783 UM007I EN P December 2017 Preface Notes ...
Страница 72: ...72 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 2 Get Started Notes ...
Страница 148: ...148 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 3 Configure Switch Features ...
Страница 282: ...282 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 3 Configure Switch Features Notes ...
Страница 317: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 317 Monitor the Switch Chapter 4 ...
Страница 319: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 319 Monitor the Switch Chapter 4 ...
Страница 325: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 325 Monitor the Switch Chapter 4 ...
Страница 338: ...338 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 5 Troubleshoot the Switch Notes ...
Страница 396: ...396 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix A DataTypes Notes ...
Страница 404: ...404 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix B Port Assignments for CIP Data Notes ...
Страница 450: ...450 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix D Cables and Connectors Notes ...
Страница 457: ......