302
Rockwell Automation Publication 1783-UM007I-EN-P - December 2017
Chapter 4
Monitor the Switch
Port Status
In the navigation pane, click Port Status.
You can monitor alarms, statuses, thresholds, and bandwidth utilization for
each switch port. You can also access port and cable diagnostics.
Table 112 - Port Status Fields
Field
Description
Unit
(Stratix 8000/8300 switches)
Indicates where the port resides:
•
Base (for example, 1783-MS10T).
•
Expansion module (for example, 1783-MX08T).
Port
Displays the selected port. The port number includes the port type (Fa for Fast Ethernet and Gi for Gigabit Ethernet) and the specific port number.
EXAMPLE:
Gi1/1 is Gigabit Ethernet port 1.
Port Alarm Status
Displays the status of the port alarm.
Valid values:
•
Link fault alarm
•
Port not forwarding alarm
•
Port not operating alarm
•
High bit error rate alarm
•
No alarms
Link Status
Displays whether the link is active or inactive.
Port Fault Status
Displays the status of the port alarm.
Valid values:
•
Error - Disable event
•
SFP error - Disabled
•
CDP native VLAN mismatch
•
MAC address flap
•
Port security violation
•
No fault
Содержание armorstratix 5700
Страница 10: ...10 Rockwell Automation Publication 1783 UM007I EN P December 2017 Table of Contents Notes ...
Страница 12: ...12 Rockwell Automation Publication 1783 UM007I EN P December 2017 Preface Notes ...
Страница 72: ...72 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 2 Get Started Notes ...
Страница 148: ...148 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 3 Configure Switch Features ...
Страница 282: ...282 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 3 Configure Switch Features Notes ...
Страница 317: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 317 Monitor the Switch Chapter 4 ...
Страница 319: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 319 Monitor the Switch Chapter 4 ...
Страница 325: ...Rockwell Automation Publication 1783 UM007I EN P December 2017 325 Monitor the Switch Chapter 4 ...
Страница 338: ...338 Rockwell Automation Publication 1783 UM007I EN P December 2017 Chapter 5 Troubleshoot the Switch Notes ...
Страница 396: ...396 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix A DataTypes Notes ...
Страница 404: ...404 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix B Port Assignments for CIP Data Notes ...
Страница 450: ...450 Rockwell Automation Publication 1783 UM007I EN P December 2017 Appendix D Cables and Connectors Notes ...
Страница 457: ......