485
S:\Hp8960\E1960A GSM Mobile Test Application\A.04 Release\Reference_Manual\Chapters\hpib_SYSTem_correction.fm
SYSTem:CORRection
SYSTem:CORRection
“Diagram Conventions” on page 213
SYSTem:CORRection[:SGAin]
Function
Sets/queries the amplitude offset value in dB, used to correct for RF path loss and also turns the
STATe ON. See
“Measurement Related Configuration” on page 563
The units, dB, are optional, if no units are specified then units default to dB.
Setting
Range:
−
100 to +100
Resolution: .1
Query
Range:
−
100 to +100
Resolution: 0.1
*RST Setting
0 dB
Programming Example
OUTPUT 714;"SYSTEM:CORRECTION:SGAIN 6" !Sets an amplitude offset of 6 dB.
?
<sp><num value>[DB]
SYSTem
<sp>1|ON|0|OFF
?
<sp><num value>[DB]
?
(returns 1|0)
[:SGAin]