![Agilent Technologies 8960 Series 10 Скачать руководство пользователя страница 263](http://html1.mh-extra.com/html/agilent-technologies/8960-series-10/8960-series-10_reference-manual_2868627263.webp)
263
S:\Hp8960\E1960A GSM Mobile Test Application\A.04 Release\Reference_Manual\Chapters\hpib_call_ms.fm
CALL:MS
CALL:MS:TXLevel:DCS
CALL:MS:TXLevel:EGSM
Function
Selects the MS uplink power control level for the DCS band. See
Additional commands can be appended to aid in controller/Mobile Station synchronization.
See
“Call Processing Subsystem Overlapped Commands” on page 33
Setting
range: 0 to 31 (default 10)
resolution: 1
Query
range: 0 to 31
resolution: 1
*RST Setting
Band: PGSM
TXLevel: 15
Programming Example
OUTPUT 714;”CALL:MS:TXLEVEL:DCS 8”
Function
Selects the MS uplink power control level for the EGSM band. See
Additional commands can be appended to aid in controller/Mobile Station synchronization. See
“Call Processing Subsystem Overlapped Commands” on page 33
Setting
range: 0 to 31 (default 15)
resolution: 1
Query
range: 0 to 31
resolution: 1
*RST Setting
Band: PGSM
TXLevel: 15
Programming Example
OUTPUT 714;”CALL:MS:TXLEVEL:EGSM 20”