CALL:RFGenerator
CALL[:CELL]:RFGenerator:POWer:AMPLItude
CALL[:CELL]:RFGenerator:POWer:STATe
Function
Set/queries Rf Gen Power.
The suffix dBm is optional.
Operating mode = Test Mode and Downlink Function = CW. see
The RF Gen Power field is affected when there is an amplitude offset, see
Related Configuration” on page 563
Setting
range: -10 to -100 dBm
resolution: .01 dBm
Query
range: -10 to -100 dBm
resolution: .01 dBm
*RST Setting
-85 dBm
Programming Example
OUTPUT 714;”CALL:CELL:RFGENERATOR:POWER:AMPLITUDE -50DBM”
Function
Sets/queries the RF Gen Power State.
Operating mode = Test Mode and Downlink Function = CW. See
Setting
range: 0 | OFF | 1 | ON
Query
range: 0 | OFF | 1 | ON
*RST Setting
ON
Programming Example
OUTPUT 714;”CALL:CELL:RFGENERATOR:POWER:STATE OFF”