CALL:PAGing
CALL:PAGing:REPeat[:STATe]
CALL:PAGing:MODE
Function
Sets/queries repeat paging state. When the state is ON paging repeats until the test set receives a
RACH. When the state is off the test set returns the No response to page timer T3113 expiry. See
“Fixed Timer Messages” on page 578
Setting
0 | OFF | 1 | ON
Query
0 | 1
*RST Setting
0|OFF
Programming Example
OUTPUT 714;”CALL:PAGING:REPEAT:STATE ON” !Turns paging repeat ON.
Function
Sets/queries the paging mode that the test set will use to page the MS. Some mobile stations can
be set to a discontinuous reception mode (DRX), which configures the MS to look for a page in a
pre-defined paging subchannel only.
When paging mode is set to Reorg (DRX off), the test set will page the MS on the paging channel
in the next available paging channel without waiting for the defined paging group.
When paging mode is set to Normal (DRX on), the test set will page the MS on the correct paging
subchannel defined by the mobile station’s paging group.
Setting
range: REORg | NORMal
Query
range: REOR | NORM
*RST Setting
Reorg
Programming Example
OUTPUT 714;”CALL:PAGING:MODE REOR” ! MS will be sent a page on the
! next available paging subchannel