CALL:BA
CALL[:CELL]:BA:TABLe[:SELected]
Function
Sets/queries the BA Table entries for the selected broadcast band. Entries are set (value entered
into table and state set to ON) using a comma separated list of 1 to 16 values. States of table
entries not included in setting list are set to OFF. Sending a null list (no values) sets states of all
table entries to OFF. Query returns a comma separated list of the table entries that are in the
ON state. If states of all table entries are set to OFF, query returns 9.91E+37 (NAN).
Setting
Depends upon the selected broadcast band:
range:
• PGSM broadcast band range: 1 to 124
• EGSM broadcast band range: 0 to 124 | 975 to 1023
• DCS broadcast band range: 512 to 885
• PCS broadcast band range: 512 to 810
resolution: 1
Query
range: 0 to 9.91 E +37
*RST Setting
Depends upon the selected broadcast band:
entries:
• PGSM BA Table: 20, 1, 62, 124, 9, 18, 36, 45, 54, 63, 72, 81, 90, 99, 108, 117
• EGSM BA Table: 20, 975, 37, 124, 986, 1008, 1019, 7, 18, 30, 53, 64, 76, 87, 99, 110
• DCS BA Table: 512, 698, 885, 537, 562, 587, 612, 637, 662, 712, 737, 762, 787, 812, 837, 862
• PCS BA Table: 512, 660, 810, 530, 550, 570, 590, 610, 630, 650, 690, 710, 730, 750, 770, 790
states:
• first entry = ON, all others = OFF
Programming Example
OUTPUT 714;”CALL:CELL:BA:TABLE:SELECTED 512,689,885” !Sets 3 table entries for the
!selected broadcast band.
!States of the remaining 13
!entries are set to OFF.
OUTPUT 714;”CALL:CELL:BA:TABLE:SELECTED” !Sets states of all table entries to OFF.