434
S:\Hp8960\E1960A GSM Mobile Test Application\A.04 Release\Reference_Manual\Chapters\hpib_setup_txpower.fm
SETup:TXPower
SETup:TXPower:COUNt:STATe
SETup:TXPower:TIMeout[:STIMe]
SETup:TXPower:TIMeout:TIME
Function
Sets/queries the TX power multi-measurement count state.
Setting
0|Off | 1|On
Query
0|1
*RST Setting
0|off
Programming Example
OUTPUT 714;"SETUP:TXPOWER:COUNT:STATE ON" !Sets the multi-measurement count
!state to on.
Function
Sets/queries TX carrier power measurement timeout value and also sets the state to on. The
units (S|MS) are optional, if no units are specified then units default to S.
Setting
Range: .1 to 999
Resolution: .1
Query
Range: .1 to 999
Resolution: .1
*RST Setting
10 seconds
Programming Example
OUTPUT 714;"SETUP:TXPOWER:TIMEOUT:STIME 20" !Sets the state to on and the
!timeout value to 20 seconds.
Function
Sets/queries the timeout value in seconds that will be used for TX power measurements. The
units (S|MS) are optional, if no units are specified then units default to S.
Setting
Range: .1 to 999
Resolution: .1
Query
Range: .1 to 999
Resolution: .1
*RST Setting
10 seconds
Programming Example
OUTPUT 714;"SETUP:TXPOWER:TIMEOUT:TIME 20" !Sets the TX power measurement
!timeout to 20 seconds.