Maintaining the Purged Packed Inlet
Consumables and Parts for the Purged Packed Inlet
74
Maintaining Your GC
Consumables and Parts for the Purged Packed
Inlet
See the Agilent catalog for consumables and supplies for a more complete listing, or visit the
Agilent Web site for the latest information (
Table 11 Purged packed inlet parts
Description
Part number/quantity
Preventative maintenance kit
5188-6498
Purged packed glass liners and column adapters
Glass liner
5080-8732 (25/pack) or
5181-3382 deactivated (5/pack)
0.53-mm column adapter
19244-80540
1/8-inch column adapter
19243-80530
1/4-inch column adapter
19243-80540
Recommended septa and O-rings for the purged packed inlet
11-mm solid septum, low-bleed, red
5181-1263 (50/pk)
11-mm septum with partial through-hole, low-bleed, red
5181-3383 (50/pk)
11-mm septum, low-bleed, gray
5080-8896 (50/pk)
Merlin Microseal septum (30 psi)
5181-8815
11-mm high-temperature silicone septum (350 °C and higher)
5182-0739 (50/pk)
Viton O-ring (Top insert weldment)
5080-8898 (12/pk)
Packed column adapters for detector
s
1/8-inch Packed column adapter assembly
G3435-81340
1/4-inch Packed column adapter assembly
G3435-81330
Table 12 Nuts and ferrules for packed columns
Description
Typical use
Part number/quantity
1/8-inch id Swagelok stainless steel nut, front ferrule,
back ferrule
1/8-inch column
5080-8751 (20 each/pk)
1/8-inch id Swagelok brass nut, front ferrule, back
ferrule
1/8-inch column
5080-8750 (20 each/pk)
1/8-inch id Vespel/ graphite ferrule
1/8-inch column
0100-1332 (10/pk)
1/8-inch id
brass tubing nut
1/8-inch column
5180-4103 (10/pk)
1/4-inch id Swagelok stainless steel nut, front ferrule,
back ferrule
1/4-inch column
5080-8753 (20 each/pk)
Содержание 8890
Страница 1: ...Agilent 8890 Gas Chromatograph Maintaining Your Gas Chromatograph GC ...
Страница 8: ...8 Maintaining Your GC ...
Страница 22: ...2 Removing Covers To Remove the Electronics Cover 22 Maintaining Your GC ...
Страница 28: ...3 Maintaining the GC To Change the Hydrogen Sensor Calibration Gas Cylinder 28 Maintaining Your GC ...
Страница 48: ...4 Maintaining Capillary Columns To Remove the Ferrule From a CFT Fitting 48 Maintaining Your GC ...
Страница 120: ...7 Maintaining the COC Inlet To Bakeout Contaminants from the COC Inlet 120 Maintaining Your GC ...
Страница 142: ...8 Maintaining the MMI To Bakeout Contaminants from the MMI 142 Maintaining Your GC ...
Страница 178: ...10 Maintaining the VI To Bakeout Contaminants from the VI Inlet 178 Maintaining Your GC ...
Страница 208: ...12 Maintaining the TCD To Bakeout Contaminants from the TCD 208 Maintaining Your GC ...
Страница 240: ...14 Maintaining the ECD To Bakeout the ECD 240 Maintaining Your GC ...
Страница 264: ...16 Maintaining EPC Modules Installing or Replacing Frits in the PCM 264 Maintaining Your GC ...
Страница 276: ...17 Maintaining a Valve To Install the Upper Valve Box 276 Maintaining Your GC ...
Страница 282: ...www agilent com Agilent Technologies Inc 2019 First edition January 2019 G2790 90015 G3540 90015 ...