![Agilent Technologies 8890 Скачать руководство пользователя страница 211](http://html.mh-extra.com/html/agilent-technologies/8890/8890_maintaining-manual_2867678211.webp)
13 Maintaining the NPD
Consumables and Parts for the NPD
Maintaining Your GC
211
.250
Ferrule, Vespel/graphite, 0.4-mm id
0.1-mm, 0.2-mm, and 0.25-mm capillary
columns
5181-3323 (10/pk)
Ferrule, graphite, 0.5-mm id
0.1-mm, 0.2-mm, 0.25-mm, and 0.32-mm
capillary columns
5080-8853 (10/pk)
Column nut, finger-tight (for .100- to
.320-mm columns)
Connect column to inlet or detector
5020-8292
.100 and .200
Ferrule, Vespel/graphite, 0.37-mm id
0.1-mm and 0.2-mm capillary columns
5062-3516 (10/pk)
Ferrule, Vespel/graphite, 0.4-mm id
0.1-mm, 0.2-mm, and 0.25-mm capillary
columns
5181-3323 (10/pk)
Ferrule, graphite, 0.5-mm id
0.1-mm, 0.2-mm, 0.25-mm, and 0.32-mm
capillary columns
5080-8853 (10/pk)
Ferrule, graphite, 0.4-mm id
500-2114 (10/pk)
Column nut, finger-tight (for .100- to
.320-mm columns)
Connect column to inlet or detector
5020-8292
All
Ferrule, no-hole
Testing
5181-3308 (10/pk)
Capillary column blanking nut
Testing–use with any ferrule
5020-8294
Column nut, universal
Connect column to inlet or detector
5181-8830 (2/pk)
Column cutter, ceramic wafer
Cutting capillary columns
5181-8836 (4/pk)
Pencil, diamond tipped
Cutting capillary columns
420-1000
Ferrule tool kit
Ferrule installation
440-1000
Table 35 Nuts, ferrules, and hardware for capillary columns (continued)
Column id (mm)
Description
Typical use
Part number/quantity
Содержание 8890
Страница 1: ...Agilent 8890 Gas Chromatograph Maintaining Your Gas Chromatograph GC ...
Страница 8: ...8 Maintaining Your GC ...
Страница 22: ...2 Removing Covers To Remove the Electronics Cover 22 Maintaining Your GC ...
Страница 28: ...3 Maintaining the GC To Change the Hydrogen Sensor Calibration Gas Cylinder 28 Maintaining Your GC ...
Страница 48: ...4 Maintaining Capillary Columns To Remove the Ferrule From a CFT Fitting 48 Maintaining Your GC ...
Страница 120: ...7 Maintaining the COC Inlet To Bakeout Contaminants from the COC Inlet 120 Maintaining Your GC ...
Страница 142: ...8 Maintaining the MMI To Bakeout Contaminants from the MMI 142 Maintaining Your GC ...
Страница 178: ...10 Maintaining the VI To Bakeout Contaminants from the VI Inlet 178 Maintaining Your GC ...
Страница 208: ...12 Maintaining the TCD To Bakeout Contaminants from the TCD 208 Maintaining Your GC ...
Страница 240: ...14 Maintaining the ECD To Bakeout the ECD 240 Maintaining Your GC ...
Страница 264: ...16 Maintaining EPC Modules Installing or Replacing Frits in the PCM 264 Maintaining Your GC ...
Страница 276: ...17 Maintaining a Valve To Install the Upper Valve Box 276 Maintaining Your GC ...
Страница 282: ...www agilent com Agilent Technologies Inc 2019 First edition January 2019 G2790 90015 G3540 90015 ...