17 Maintaining a Valve
Consumables and Parts for Valves
266
Maintaining Your GC
Consumables and Parts for Valves
See the Agilent catalog for consumables and supplies for a more complete listing, or visit the
Agilent Web site for the latest information (
).
Table 43 Valve supplies
Description
Part number
Valves, gas sampling
6-port, 300 psi
0101-0584
6-port, 400 psi, 225 °C maximum temperature
5062-9508
6-port, 300 °C maximum temperature
0101-0460
6-port Hastelloy, 400 psi, 225 °C maximum temperature
5062-9509
10-port, 400 psi, 225 °C maximum temperature
5062-9510
10-port Nitronic 60, 300 psi, 350 °C maximum temperature
0101-0585
10-port Hastelloy, 400 psi, 225 °C maximum temperature
5062-9511
Valves, liquid sampling
0.2-µL, 1000 psi, stainless steel, 175 °C maximum temperature
0101-0636
0.5-µL, 5000 psi, 175 °C maximum temperature
0101-0639
0.5-µL, 1000 psi, stainless steel, 175 °C maximum temperature
0101-0637
1.0-µL, 1000 psi, stainless steel, 175 °C maximum temperature
0101-0638
Gas sampling valve sample loops
0.25-cc 0101-0303
0.50-cc 0101-0282
1.00-cc 0101-0299
2.00-cc 0101-0300
2.0-mL nickel loop, 1/16-inch
0101-0955
5.00-cc 0101-0301
10.00-cc 0101-0302
Ferrule, 1/16-inch stainless steel (10/pk)
5181-1291
Nut, 1/16-inch (10/pk)
5181-1292
Содержание 8890
Страница 1: ...Agilent 8890 Gas Chromatograph Maintaining Your Gas Chromatograph GC ...
Страница 8: ...8 Maintaining Your GC ...
Страница 22: ...2 Removing Covers To Remove the Electronics Cover 22 Maintaining Your GC ...
Страница 28: ...3 Maintaining the GC To Change the Hydrogen Sensor Calibration Gas Cylinder 28 Maintaining Your GC ...
Страница 48: ...4 Maintaining Capillary Columns To Remove the Ferrule From a CFT Fitting 48 Maintaining Your GC ...
Страница 120: ...7 Maintaining the COC Inlet To Bakeout Contaminants from the COC Inlet 120 Maintaining Your GC ...
Страница 142: ...8 Maintaining the MMI To Bakeout Contaminants from the MMI 142 Maintaining Your GC ...
Страница 178: ...10 Maintaining the VI To Bakeout Contaminants from the VI Inlet 178 Maintaining Your GC ...
Страница 208: ...12 Maintaining the TCD To Bakeout Contaminants from the TCD 208 Maintaining Your GC ...
Страница 240: ...14 Maintaining the ECD To Bakeout the ECD 240 Maintaining Your GC ...
Страница 264: ...16 Maintaining EPC Modules Installing or Replacing Frits in the PCM 264 Maintaining Your GC ...
Страница 276: ...17 Maintaining a Valve To Install the Upper Valve Box 276 Maintaining Your GC ...
Страница 282: ...www agilent com Agilent Technologies Inc 2019 First edition January 2019 G2790 90015 G3540 90015 ...