12 Maintaining the TCD
Consumables and Parts for the Thermal Conductivity Detector
202
Maintaining Your GC
Consumables and Parts for the Thermal
Conductivity Detector
See the Agilent catalog for consumables and supplies for a more complete listing, or visit the
Agilent Web site for the latest information (
Standard TCD column hardware
Table 32 Nuts, ferrules, and hardware for capillary columns
Column id (mm)
Description
Typical use
Part number/quantity
.530
Ferrule, Vespel/graphite, 0.8-mm id
0.45-mm and 0.53-mm capillary columns
5062-3512 (10/pk)
Ferrule, graphite, 1.0-mm id
0.53-mm capillary columns
5080-8773 (10/pk)
Ferrule, graphite, 0.8-mm id
0.53-mm capillary columns
500-2118 (10/pk)
Column nut, finger-tight (for
0.53-mm columns)
Connect column to inlet or detector
5020-8293
.320
Ferrule, Vespel/graphite, 0.5-mm id
0.32-mm capillary columns
5062-3514 (10/pk)
Ferrule, graphite, 0.5-mm id
0.1-mm, 0.2-mm, 0.25-mm, and 0.32-mm
capillary columns
5080-8853 (10/pk)
Column nut, finger-tight (for .100- to
.320-mm columns)
Connect column to inlet or detector
5020-8292
.250
Ferrule, Vespel/graphite, 0.4-mm id
0.1-mm, 0.2-mm, and 0.25-mm capillary
columns
5181-3323 (10/pk)
Ferrule, graphite, 0.5-mm id
0.1-mm, 0.2-mm, 0.25-mm, and 0.32-mm
capillary columns
5080-8853 (10/pk)
Column nut, finger-tight (for .100- to
.320-mm columns)
Connect column to inlet or detector
5020-8292
.100 and .200
Ferrule, Vespel/graphite, 0.37-mm id
0.1-mm and 0.2-mm capillary columns
5062-3516 (10/pk)
Ferrule, Vespel/graphite, 0.4-mm id
0.1-mm, 0.2-mm, and 0.25-mm capillary
columns
5181-3323 (10/pk)
Ferrule, graphite, 0.5-mm id
0.1-mm, 0.2-mm, 0.25-mm, and 0.32-mm
capillary columns
5080-8853 (10/pk)
Ferrule, graphite, 0.4-mm id
500-2114 (10/pk)
Column nut, finger-tight (for .100- to
.320-mm columns)
Connect column to inlet or detector
5020-8292
All
Ferrule, no-hole
Testing
5181-3308 (10/pk)
Capillary column blanking nut
Testing–use with any ferrule
5020-8294
Column nut, universal
Connect column to inlet or detector
5181-8830 (2/pk)
Column cutter, ceramic wafer
Cutting capillary columns
5181-8836 (4/pk)
Pencil, diamond tipped
Cutting capillary columns
420-1000
Ferrule tool kit
Ferrule installation
440-1000
Содержание 8890
Страница 1: ...Agilent 8890 Gas Chromatograph Maintaining Your Gas Chromatograph GC ...
Страница 8: ...8 Maintaining Your GC ...
Страница 22: ...2 Removing Covers To Remove the Electronics Cover 22 Maintaining Your GC ...
Страница 28: ...3 Maintaining the GC To Change the Hydrogen Sensor Calibration Gas Cylinder 28 Maintaining Your GC ...
Страница 48: ...4 Maintaining Capillary Columns To Remove the Ferrule From a CFT Fitting 48 Maintaining Your GC ...
Страница 120: ...7 Maintaining the COC Inlet To Bakeout Contaminants from the COC Inlet 120 Maintaining Your GC ...
Страница 142: ...8 Maintaining the MMI To Bakeout Contaminants from the MMI 142 Maintaining Your GC ...
Страница 178: ...10 Maintaining the VI To Bakeout Contaminants from the VI Inlet 178 Maintaining Your GC ...
Страница 208: ...12 Maintaining the TCD To Bakeout Contaminants from the TCD 208 Maintaining Your GC ...
Страница 240: ...14 Maintaining the ECD To Bakeout the ECD 240 Maintaining Your GC ...
Страница 264: ...16 Maintaining EPC Modules Installing or Replacing Frits in the PCM 264 Maintaining Your GC ...
Страница 276: ...17 Maintaining a Valve To Install the Upper Valve Box 276 Maintaining Your GC ...
Страница 282: ...www agilent com Agilent Technologies Inc 2019 First edition January 2019 G2790 90015 G3540 90015 ...