Front-Panel Menu Reference
A: MEASurement MENU
1: DIG FILTER
Ø
2: INTEGRATE
Ø
3: OCOMP
Ω
Ø
4: LOW POWER
Ω
Ø
5: LOW VOLT
Ω
Ø
6: LoV LIMIT
Ω
1: DIG FILTER
Selects the digital filter speed. Can be set to FAST, MEDIUM, or SLOW.
2: INTEGRATE
Sets the measurement integration time.
3: OCOMP
Ω
Enables or disables offset compensation for resistance measurements.
4: LOW POWER
Ω
Enables or disables low power ohms measurements.
5: LOW VOLT
Ω
Enables or disables voltage limited resistance measurements.
6: LoV LIMIT
Ω
Sets the voltage limit for voltage limited resistance measurements.
B: TEMPerature MENU
1:PROBE TYPE
Ø
2: UNITS
Ø
3: RTD TYPE
Ø
4:RTD Ro
Ø
5:T/C TYPE
Ø
6: COLD JUNCT
Ø
7:JUNCT TEMP
1: PROBE TYPE
Selects thermocouples, thermistors, or RTDs as the temperature probe.
2: UNITS
Sets the measurement units to either
°
C,
°
F, or Kelvins.
3: RTD TYPE
Sets the type of RTD in use.
4: RTD Ro
Sets the nominal (0
°
C) value for the RTD in use.
5: T/C TYPE
Selects the type of thermocouple in use.
6: COLD JUNCT
Sets the source of the temperature reference junction.
7: JUNCT TEMP
Allows direct entry of reference junction temperature.
C: MATH MENU
1: STATS
Ø
2: NULL VALUE
Ø
3: SCALE GAIN
Ø
4 : SCALE OFST
1:STATS
Recalls the values of minimum, maximum, standard deviation, average,
peak-to-peak, and number of readings.
2: NULL VALUE
Selects independent null settings for voltage on channels 1 and 2, resistance,
and temperature functions.
3: SCALE GAIN
Sets the gain for linear scaling of the data.
4: SCALE OFST
Sets the offset for linear scaling of data.
D: TRIGger MENU
1: READ HOLD
Ø
2: TRIG DELAY
Ø
3: N SAMPLES
1: READ HOLD
Selects the reading hold sensitivity band.
2: TRIG DELAY
Specifies a time delay between the trigger and the start of the measurement.
3: N SAMPLES
Sets the number of samples taken per trigger.
2
Chapter 2 Front-Panel Operation
Front-Panel Menu Reference
31
Содержание 34420A
Страница 1: ......
Страница 2: ......
Страница 13: ...1 Quick Start ...
Страница 31: ...2 Front Panel Operation ...
Страница 55: ...3 Features and Functions ...
Страница 117: ...4 Remote Interface Reference ...
Страница 200: ...5 Error Messages ...
Страница 213: ...6 Application Programs ...
Страница 245: ...6 Chapter 6 Application Programs Microsoft Excel Macro Example 245 ...
Страница 246: ...Chapter 6 Application Programs Microsoft Excel Macro Example 246 ...
Страница 247: ...7 Measurement Tutorial ...
Страница 274: ...8 Specifications ...
Страница 279: ...Dimensions Chapter 8 Specifications 34420A Nano Volt Micro Ohm Meter 280 ...
Страница 294: ......