ELECTRICAL SYSTEM
FUSE CHECK/REPLACEMENT
Disconnect the battery connector (12).
Move aside the recovery water drain hose (16).
Remove the battery charger cable (I) from the cable holder (J).
Remove the screws (A) and carefully move aside the panel (B) by disengaging the grommet (K) from its housing on the
panel (B).
Check/replace the following fuses:
(C) - F1 fuse, deck: (40 A)
(D) - F2 fuse, vacuum system: (30 A)
(E) - F3 fuse, drive system: (30 A) (*)
(F) - F4 fuse, signal circuits: (3 A)
(G) - F5 fuse, brush/pad-holder release: (20 A) (*)
(H) - F6 fuse, pumps: (3 A) (*)
(*) Only for
Adfinity
TM