
SERVICE MANUAL
ENGLISH
Adfinity
TM
17 ST, 20 ST, 20 D, X 20 D, X 20 C, X 24 D
9096982000(1)2007-02
55
ELECTRICAL SYSTEM
MACHINE WORKING HOUR CHECK (optional)
(For.
Adfinity
TM
20 D, X 20 D, X 20 C, X 24 D
) Turn the ignition key (80) to “I”.
Press the vacuum system switch (73) and read on the hour counter (79) the total number of working hours (scrubbing/
drying) performed by the machine.
Turn off the vacuum system by pressing the switch (73).
(For.
Adfinity
TM
20 D, X 20 D, X 20 C, X 24 D
) Turn the ignition key (80) to “0”.
BATTERY CHARGE AND MAINTENANCE
See the User Manual.
BATTERY DISASSEMBLY/ASSEMBLY
Disassembly
If the tank (21) contains recovery water:
Drive the machine to the appointed recovery water disposal area.
(For.
Adfinity
TM
20 D, X 20 D, X 20 C, X 24 D
) Turn the ignition key (80) to “0”.
(For.
Adfinity
TM
17 ST, 20 ST
) Turn off the switches (71) and (73).
Empty the recovery water tank (21) with the hose (16).
Drive the machine on a level floor.
•. (For.
Adfinity
TM
20 D, X 20 D, X 20 C, X 24 D
) Turn the ignition key (80) to “0”.
(For.
Adfinity
TM
17 ST, 20 ST
) Turn off the switches (71) and (73).
Disconnect the battery connector (12).
Grasp the handle (41) and carefully lift the tank (40).
Disconnect the cables (A) from the battery terminals.
Remove the battery shims, if present.
Carefully remove the batteries (B).
Assembly
Assemble the batteries in the reverse order of disassembly, referring to the installation diagram (C), and note the following:
Set the machine according to the type of batteries installed (WET or GEL) as shown in the relevant paragraph.
1.
2.
3.
4.
1.
•
•
•
•
2.
3.
•
4.
5.
6.
7.
8.
9.
•
A
B
C
A
B
S301566A