SERVICE MANUAL
ENGLISH
Adfinity
TM
17 ST, 20 ST, 20 D, X 20 D, X 20 C, X 24 D
9096982000(1)2007-02
41
RECOVERY WATER SYSTEM
RECOVERY WATER TANK AND VACUUM GRID CLEANING, AND COVER GASKET CHECK
Drive the machine to the appointed recovery water disposal area.
•. (For.
Adfinity
TM
20 D - X 20 D - X 20 C - X 24 D
) Turn the ignition key (80) to “0”.
(For.
Adfinity
TM
17 ST - 20 ST
) Turn off the switches (71) and (73).
Lift the cover (A) to washing position (L).
Wash with clean water the cover (A), the tank (B) and the vacuum grid with automatic shut-off float (D).
Drain the water in the tank through the hose (16).
If necessary, release the fasteners (E) and open the grid (D), recover the float (F), clean all the components and then
reinstall them.
Check the tank cover gasket (G) for integrity.
NOTE
The gasket (G) creates vacuum in the tank that is necessary for vacuuming the recovery water.
If necessary replace the gasket (G) by removing it from its housing (H). When assembling the new gasket, install the
joint (I) in the rear central area, as shown in the figure.
Check that the bearing surface (J) of the gasket (G) is integral and adequate for the gasket itself.
Check the compensation hole (K) for clogging, and clean it if necessary.
NOTE
The hole (K), allowing to compensate the air in the cover interspaces, contributes to create vacuum in the
tank.
Close the cover (A).
NOTE
Figure showing Adfinity
TM
X 20 C.
1.
2.
•
3.
4.
5.
6.
7.
8.
9.
H
D
E
E
F
G
I
L
K
G
A
B
J
S301551A