SERVICE MANUAL
ENGLISH
Adfinity
TM
17 ST, 20 ST, 20 D, X 20 D, X 20 C, X 24 D
9096982000(1)2007-02
15
SOLUTION/CLEAN WATER SUPPLY SYSTEM
SOLUTION/CLEAN WATER TANK AND SUPPLY SYSTEM CLEANING
Drive the machine to the appointed solution disposal area.
• (For Adfinity
TM
20 D - X 20 D - X 20 C - X 24 D) Turn the ignition key (80) to “0”.
(For Adfinity
TM
17 ST - 20 ST) Turn off the switches (71) and (73).
Empty the solution/clean water tank (20) with the hose (17).
Start the machine (as shown in the User Manual) and keep it running until the solution/clean water tank is completely
empty.
• (For Adfinity
TM
20 D - X 20 D - X 20 C - X 24 D) Turn the ignition key (80) to “0”.
(For Adfinity
TM
17 ST - 20 ST) Turn off the switches (71) and (73).
Clean the tank (20) with clean water.
Start the machine (as shown in the User Manual) and keep it running until the solution/clean water tank is completely
empty.
Clean the solution filter (see the following procedure).
SOLUTION FILTER CLEANING (For Adfinity
TM
17 ST - 20 ST)
Drive the machine on a level floor.
Turn off the switches (71) and (73).
Close the solution tap (A) under the machine left lower side. The tap (A) is closed when it is on the position (B) and it is
open when it is on the position (C).
Remove the transparent cover (D), then remove the filter strainer (E). Clean and install them on the support (F).
NOTE
The filter strainer (E) must be correctly positioned on the housing (G) of the support (F).
Open the tap (A).
1.
2.
•
3.
4.
5.
•
6.
7.
8.
1.
2.
3.
4.
5.
E
G
F
E
D
A
C
B
S301520A