![ADEMCO VISTA-100 Скачать руководство пользователя страница 181](http://html1.mh-extra.com/html/ademco/vista-100/vista-100_installation-instructions-manual_2850251181.webp)
– 171 –
Section 28: KEYPAD FUNCTIONS
This section provides the following information:
• General information about keypad usage
• Basic keypad functions
• Global arming
• Access control
• Delaying closing time
• Executing the "Go To" command
• Viewing:
A user's capabilities
Zone descriptors
Downloaded messages
Built-in user's guide
• Speed key macro commands
• Executing #70 Manual Relay Activation mode
General Information
The keypad allows the user to arm and disarm the system, and perform
other system functions, such as bypassing zones, viewing messages from the
central station, and displaying zone descriptors. Zone and system conditions
(alarm, trouble, bypass) are shown in the display window.
When an alarm occurs, keypad sounding and external sounding will occur,
and the zone(s) in alarm will be displayed on the keypad. Pressing any key
will silence the keypad sounder for 10 seconds. Disarming the system will
silence both keypad and external sounders. When the system is disarmed,
any zones that were in an alarm condition during the armed period will be
displayed (memory of alarm). To clear this display, simply repeat the disarm
sequence (enter the security code and press the OFF key).
The keypads also feature chime annunciation, and 3 panic keys (for silent,
audible, fire or personal emergency alarms) which can notify the central
station of an alarm condition, if that service is connected.
Arming Functions
The following is a brief list of system commands. For detailed information
concerning system functions, refer to the User's Manual.
Display Faulted
Before arming, the system must be in the READY
Zones
condition (all zones must be intact). If the "NOT READY" message appears,
press the READY
✴
key to display faulted zones.
Arming Away
Enter code + 2 (AWAY)
Arming Stay
Enter code + 3 (STAY) (all zones designated as zone types 4 and 10 will be
automatically bypassed).
Arming Instant
Enter code + 7 (INSTANT) (same as STAY without entry delay).
Arming Maximum
Enter code + 4 (MAXIMUM) (same as AWAY without entry delay).
Disarming
Enter code + 1 (OFF).
Bypassing Zones
Enter code + 6 (BYPASS) + 3-digit zone number. To automatically bypass
all faulted zones, use "Quick Bypass" method: Enter code + # .
Fire and System zones may only be bypassed by those users enabled
in field 3*85.
Chime Mode
Enter code + 9 (CHIME). To turn chime mode off, enter code + CHIME
again.
Quick Arming:
Note that if QUICK ARM is enabled (field *29), the # key can be pressed
instead of entering the security code, for any of the arming procedures
(Away, Stay, Instant, Maximum, etc.).
www.PDF-Zoo.com
firealarmresources.com
Содержание VISTA-100
Страница 197: ... 187 Insert DIP Switch Table Board A www PDF Zoo com firealarmresources com ...
Страница 198: ... 188 Insert DIP Switch Table Board B www PDF Zoo com firealarmresources com ...
Страница 199: ... 189 Insert DIP Switch Table Board C www PDF Zoo com firealarmresources com ...
Страница 206: ... 196 NOTES www PDF Zoo com firealarmresources com ...