–8–
The following chart sums up how the common lobby partition will operate, if
different options are set for another partition in fields 1*18 and 1*19.
1*18
1*19
Disarms when
Attempts to arm when Can be armed if
Affects Lobby
Arms Lobby
partition disarms?
partition arms?
other partitions
disarmed?
0
0
NO
NO
YES
1
0
YES
NO
NO
1
1
YES
YES
NO
0
1
---ENTRY NOT ALLOWED---
Example
Here is an example of how the lobby would react in a typical setup.
MAIN ENTRANCE
OFFICE #1
OFFICE #2
COMMON LOBBY
User #1 has access to Office #1 and the Common Lobby.
User #2 has access to Office #2 and the Common Lobby.
Office #1 is set up to affect the Common Lobby, but not arm it.
Office #2 is set up to affect and arm the Common Lobby.
For the purpose of this example, the ( ) indicate the current status of the other
partition when the user takes action.
Sequence #1:
Office 1
Office 2
Lobby Action
User #1: Disarms
(Armed)
Disarms
User #2:
(Disarmed) Disarms
No Change
User #1:
Arms
(Disarmed)
No change
User #2:
(Armed)
Arms
Arms
Sequence #2:
Office 1
Office 2
Lobby Action
User #2:
(Armed)
Disarms
Disarms
User #1:
Disarms
(Disarmed)
(No change)
User #2:
(Disarmed) Arms
No Change
User #1:
Arms
(Armed)
No Change
Notice that in sequence #1, since Office #2 was the last to arm, the lobby also
armed (Office #2 is programmed to affect
and arm the lobby). In sequence #2,
the lobby could not arm when Office #2 armed, because Office #1, which affects
the lobby, was still disarmed.
When Office #1 armed, the lobby still did not arm because Office #1 was not
programmed to arm the lobby. User #1 would have to arm the lobby manually.
Therefore, you would want to program a partition to affect
and arm the lobby, if
the users of that partition are expected to be the "last out" of the building.
www.PDF-Zoo.com
firealarmresources.com
Содержание VISTA-100
Страница 197: ... 187 Insert DIP Switch Table Board A www PDF Zoo com firealarmresources com ...
Страница 198: ... 188 Insert DIP Switch Table Board B www PDF Zoo com firealarmresources com ...
Страница 199: ... 189 Insert DIP Switch Table Board C www PDF Zoo com firealarmresources com ...
Страница 206: ... 196 NOTES www PDF Zoo com firealarmresources com ...