– 160 –
Section 25: DOWNLOADING PRIMER
(Remote Downloading is not a UL Listed feature)
This section provides the following information:
• General information about downloading
• Getting on-line with a control panel
• Advisories
• Access security
• Connecting the 4100SM module for direct wire downloading
General Information
Downloading allows the operator to remotely access, program, and control
the security system over normal telephone lines. Anything that can be done
directly from the keypad can be done remotely, using ADEMCO's VLINK®
downloading software. To communicate with the control panel, the following
is required:
1.
An IBM PC compatible 286, 386, or 486 computer with at least 1MB
RAM, a hard disk with 12MB available disk space, running MS DOS 3.1
or higher operating system.
2.
One of the following modems:
•
Hayes Smartmodem 1200 (external: level 1.2 or higher; internal:
level 1.1 or higher),
•
Hayes Optima 24 + Fax 96 external.
Other brands are not compatible, even if claimed to be 100% compatible.
Internal modems must have 4 position DIP switch. Modems with 6 position
DIP switch will not work.
3.
Alternatively, you may use a 4100SM interface module to "direct wire"
the control panel to your computer at the site.
4.
V-LINK® DOWNLOADING software, from ADEMCO. This software is
available on both 3-1/2" and 5-1/4" diskettes, and includes a complete
User's Manual.
Getting On-Line with a Control Panel
At the protected premises, the Control panel must be connected to the
existing telephone line (refer to the PHONE LINE CONNECTIONS section).
No programming of the panel is required before downloading to an initial
installation.
To download, do the following:
1.
Enter the installer code + [#] + [5]. The panel temporarily enables a ring
count of 5 and sets the Download Callback option to "1" (callback not
required).
2.
Call the panel using the downloader software set to "FIRST
COMMUNICATION" mode.
3.
The downloader will establish a session with no callback. The panel
information can then be downloaded.
In order to remotely access, control, or program the alarm panel, a "link"
must be established between the computer and the control panel, as
follows:
www.PDF-Zoo.com
firealarmresources.com
Содержание VISTA-100
Страница 197: ... 187 Insert DIP Switch Table Board A www PDF Zoo com firealarmresources com ...
Страница 198: ... 188 Insert DIP Switch Table Board B www PDF Zoo com firealarmresources com ...
Страница 199: ... 189 Insert DIP Switch Table Board C www PDF Zoo com firealarmresources com ...
Страница 206: ... 196 NOTES www PDF Zoo com firealarmresources com ...