– 133 –
Extend Closing
•
A user can manually extend the arm (closing) time window
Window
by 1 or 2 hours. This is done by entering a keypad command
(user code + #82), which then prompts the user to enter the
desired extension time of 1 or 2 hours (refer to the SYSTEM
OPERATION section of the Installation Instructions). This
feature is useful if a user must stay on the premises later than
usual.
Force Arm
•
The Enable Force Arm option causes the panel to attempt to
bypass any faulted zones prior to auto-arming (panel will
perform a force-arm). This option is set in partition-specific
program field 2*08.
Auto Disarming
•
The system can automatically disarm at the end of a pre -
determined time window, if the system has not been disarmed
manually. The disarming time can be delayed by using the auto
disarm delay feature. In addition, the system can restrict
disarming to a pre-determined time.
Disarm Delay
•
Auto-disarm delay provides a delay before Auto disarming. This
delay is added to the end of the disarm window. The delay is set
in 4 minute increments, up to 56 minutes, in partition-specific
program field 2*07.
Restrict
•
This option, set in partition-specific field 2*10, allows
Disarming
disarming by operator level users only during the disarm time
window, the arming window (in case user needs to reenter
premises after arming), or when the system is in alarm.
Exception
•
This option allows a means of reporting openings and
Reports
closings by exception (sent only if event occurs outside of the
predetermined opening/closing time windows).
•
The system sends missed open/close reports if no
opening/closing occurs by the end of the corresponding window.
Time Driven
•
By using time windows, the system can automatically
Events
activate and de-activate relays at pre-detemined times to turn
lights or other devices on and off.:
•
The system can perform the same actions on a daily basis, or
can be made to perform an action only once (i.e., turn on the
porch light this Wednesday at 8:00pm).
•
The system also provides up to 20 "timers" available to the end
user for the purpose of activating output devices at preset times
and on preset days.
Limitation of
•
A user's access can be limited to a certain time period, during
Access By Time
which he can perform system functions. Outside this time, that
user's code will be inactive. The system provides up to 8 Access
Schedules, each consisting of two Time Windows (one for
opening, one for closing) for each day of the week and two time
windows for holidays. The access schedules are programmed
via #80 Menu Mode, and enabled for a given user when that
user is added to the system. If a user tries to operate the
system outside of the schedule, the alpha keypad will display
"Access Denied."
www.PDF-Zoo.com
firealarmresources.com
Содержание VISTA-100
Страница 197: ... 187 Insert DIP Switch Table Board A www PDF Zoo com firealarmresources com ...
Страница 198: ... 188 Insert DIP Switch Table Board B www PDF Zoo com firealarmresources com ...
Страница 199: ... 189 Insert DIP Switch Table Board C www PDF Zoo com firealarmresources com ...
Страница 206: ... 196 NOTES www PDF Zoo com firealarmresources com ...