– 110 –
UL
Fields 2*05 – 2*08 must be set to "0" for UL installations.
2*05
AUTO-ARM DELAY (partition-specific)
[15] |
Enter the time between the end of the arming window and the start of
auto arm warning time in values of 01-14 times 4 minutes. Enter 00 if no
delay is desired. Enter 15 if auto arming is not desired.
2*06
AUTO-ARM WARNING PERIOD (partition-specific)
[00] |
Enter the time 01-15 in one minute increments during which the user is
warned by a keypad sounding and display to exit the premises prior to
auto arming of the system. Enter 00 to disable the warning period.
2*07
AUTO-DISARM DELAY (partition-specific)
[15] |
Enter the time between the end of the disarming window and the start of
auto disarming of the system in values of 01-14 times 4 minutes. Enter
00 if no delay is desired. Enter 15 if auto disarming is not desired.
2*08
ENABLE FORCE ARM FOR AUTO-ARM
[0]
(partition-specific)
Enter 1 if the system should automatically bypass any faulted zones
when it attempts to auto arm. Otherwise enter 0.
2*09
OPEN/CLOSE REPORTS BY EXCEPTION
[0]
(partition-specific)
Enter 1 if it is desired that open/close reports be sent only if the
openings/closings occur outside the arm and disarm windows. Open
reports will also be suppressed during the closing window in order to
prevent false alarms if the user arms the system, then reenters the
premises to retrieve a forgotten item. Note that openings and closings
are still recorded in the event log. Enter 0 if exception reporting is not
desired. Note: This field must be set to 1 if "No Opening" and "No
Closing" reports are to be sent.
2*10
ALLOW DISARMING ONLY DURING ARM/DISARM
[0]
WINDOWS (partition-specific)
Enter 1 if disarming of the system should be allowed only during the
arming/disarming windows, or if the system is in alarm (if 2*11 is set to
"1"). Note that this applies only to operator level users. Installer, Master
and manager level users can disarm the system at any time. Enter 0 if
disarming can occur at any time.
0=disable for displayed partition; 1=enable for displayed partition
2*11
ALLOW DISARM OUTSIDE WINDOW IF
[1]
ALARM OCCURS
Used only if field 2*10 (partition-specific field) is set to 1.
Enter 1 to allow the system to be disarmed outside the programmed
disarm (opening) window if an alarm has occurred. Enter 0 to allow
disarming only during the disarm window, regardless of system status. If
field 2*10 is set to 0 for a partition, this field (2*11) has no effect for that
partition.
www.PDF-Zoo.com
firealarmresources.com
Содержание VISTA-100
Страница 197: ... 187 Insert DIP Switch Table Board A www PDF Zoo com firealarmresources com ...
Страница 198: ... 188 Insert DIP Switch Table Board B www PDF Zoo com firealarmresources com ...
Страница 199: ... 189 Insert DIP Switch Table Board C www PDF Zoo com firealarmresources com ...
Страница 206: ... 196 NOTES www PDF Zoo com firealarmresources com ...