SGM3000 Series Smart Meters
User Manual
90
GEH-7111-1.00-2
Restricted
Category
Standards
Terminals
10 primary, 2 supply relay, 2 auxiliary load
Protocols
IEC (DLMS/COSEM) or ANSI
Optical Port
IEC62056-21 (physical)
– ANSI C12.18
Home Area Network
ZigBee / Smart Energy 1.1
TOU Rates
10 per element
Password Protection
4 levels of password protected user access
Load Profile
Multiple data channels, 4 load profile intervals
Sufficient memory for ~ 2 years 4 channel 30 minute data
Data Storage
64 kB EEPROM, 4 MB serial flash, 16 MB SDRAM
Operating Temperature
–25 °C to +60 °C
(
–40 °C to + 70 °C limit range of operation)
Humidity
95% non-condensing
Ingress Protection
IP54
Weight
~ 2.7 kg
Table 23 Standards Compliance
Category
Standards
Agency Approval
NMI M 6 Pattern Approved (2nd edition)
MID Approved
ACMA C-Tick
Metrology Standards
General:
AS 62052.11, AS 62053.21 Class 1
Wh, AS 62053.23 Class 2 varh
IEC 62052-11, IEC 62053-21 Class 1
Wh, IEC 62053-23 Class 2 varh
AS 1284.5, AS 1284.1
EN 50470-1 Class B, EN 50470-3
Class B
NZ COP 10.4 (EGR D4)
Timekeeping:
AS 62054.21, IEC 62054-21
Load Control:
AS 62052.21, IEC 62052-21
Optical Port Physical:
AS 1284.10.2-2006, ANSI C12.18 or
IEC 62056-21
Protocol and Data Types: ANSI C12.18/C12.19 or
DLMS/COSEM
Pulse Output:
IEC 62053-31
Table 24 Standards Supported
Agency Approvals
ACMA C-Tick, NMI M6, EGR D4, MID
Metering Standards
General: IEC 62052-11, IEC 62053-21 Class 1 Wh, IEC 62053-23
Class 2 varh, IEC 62054-21
Optical Port: IEC 62056-21 or ANSI C12.18
Protocol / Data Model: DLMS/COSEM or ANSI C12.18/19