DI1(INV)
See selection DI1(INV).
-1
NOT SEL
No reset signal
0
DI1
Reset through digital input DI1. 1 = active, 0 = inactive.
1
DI2
See selection DI1.
2
DI3
See selection DI1.
3
DI4
See selection DI1.
4
DI5
See selection DI1.
5
STATE 1
Reset during state transition to state 1. Counter is reset, when the state has
been reached.
6
STATE 2
Reset during state transition to state 2. Counter is reset, when the state has
been reached.
7
STATE 3
Reset during state transition to state 3. Counter is reset, when the state has
been reached.
8
STATE 4
Reset during state transition to state 4. Counter is reset, when the state has
been reached.
9
STATE 5
Reset during state transition to state 5. Counter is reset, when the state has
been reached.
10
STATE 6
Reset during state transition to state 6. Counter is reset, when the state has
been reached.
11
STATE 7
Reset during state transition to state 7. Counter is reset, when the state has
been reached.
12
STATE 8
Reset during state transition to state 8. Counter is reset, when the state has
been reached.
13
SEQ PROG RST
Reset signal source defined by parameter
SEQ PROG RESET
14
8420
ST1 REF SEL
Selects the source for the sequence programming state 1 reference.
Parameter is used when parameter
SEQ PROG / AI1+SEQ PROG / AI2+SEQ PROG.
Note:
Constant speeds in group
overwrite the
selected sequence programming reference.
0
COMM
COMM VALUE 2. For scaling, see
on
page
.
-1.3
AI1/AI2
Reference is calculated with the following equation:
REF = AI1(%) · (50% / AI2 (%))
-1.2
AI1-AI2
Reference is calculated with the following equation:
REF = AI1(%) + 50% - AI2(%)
-1.1
AI1*AI2
Reference is calculated with the following equation:
REF = AI(%) · (AI2(%) / 50%)
-1.0
AI1+AI2
Reference is calculated with the following equation:
REF = AI1(%) + AI2(%) - 50%
-0.9
DI4U,5D
Digital input 4: Reference increase. Digital input DI5: Reference decrease.
-0.8
DI3U,4D
Digital input 3: Reference increase. Digital input DI4: Reference decrease.
-0.7
DI3U,4DR
Digital input 3: Reference increase. Digital input DI4: Reference decrease.
-0.6
Parameters – complete descriptions
Index Name/Selection
Description
Def, FbEq
Содержание ACS350 Series
Страница 1: ...ACS350 User s Manual ACS350 Drives 0 37 22 kW 0 5 30 HP ...
Страница 4: ......
Страница 8: ...Safety 8 ...
Страница 18: ...Table of contents 18 ...
Страница 24: ...Hardware description 24 ...
Страница 44: ...Installation checklist 44 ...
Страница 56: ...Start up control with I O and ID Run 56 ...
Страница 140: ...Program features 140 ...
Страница 242: ...Actual signals and parameters 242 ...
Страница 266: ...Fieldbus control with embedded fieldbus 266 ...
Страница 284: ...Fault tracing 284 ...
Страница 288: ...Maintenance and hardware diagnostics 288 ...
Страница 309: ...Dimensions 309 Frame size R2 IP20 NEMA 1 3AFE68586658 A Frame size R2 IP20 NEMA 1 VAR EMC ...
Страница 311: ...Dimensions 311 Frame size R3 IP20 NEMA 1 3AFE68579872 B Frame size R3 IP20 NEMA 1 VAR EMC ...
Страница 312: ...Dimensions 312 Frame size R4 IP20 cabinet installation UL open Frame size R4 cabinet installation UL open 3AFE68935644 ...
Страница 313: ......