Technical data
302
Brake resistors
ACS350 drives have an internal brake chopper as standard equipment. The brake
resistor is selected using the table and equations presented in this section.
Brake resistor selection
1. Determine the required maximum braking power
P
Rmax
for the application.
P
Rmax
must be smaller than
P
BRmax
given in the table on page
for the used drive
type.
2. Calculate resistance
R
with Equation 1.
3. Calculate energy
E
Rpulse
with Equation 2.
4. Select the resistor so that the following conditions are met:
• The rated power of the resistor must be greater than or equal to
P
Rmax
.
• Resistance
R
must be between
R
min
and
R
max
given in the table for the used
drive type.
• The resistor must be able to dissipate energy
E
Rpulse
during the braking
cycle
T
.
Equations for selecting the resistor:
where
R
= selected brake resistor value (ohm)
P
Rmax
= maximum power during the braking cycle (W)
P
Rave
= average power during the braking cycle (W)
E
Rpulse
= energy conducted into the resistor during a single braking pulse (J)
t
on
= length of the braking pulse (s)
T
= length of the braking cycle (s).
P
Rmax
·
150000
P
Rmax
P
Rave
=
t
on
T
R
=
t
on
P
Rmax
P
Rave
T
Eq. 1.
Eq. 3.
For conversion, use 1 HP = 746 W.
450000
P
Rmax
U
N
= 200…240 V:
U
N
= 380…415 V:
R
=
P
Rmax
·
E
Rpulse
=
t
on
Eq. 2.
615000
P
Rmax
U
N
= 415…480 V:
R
=
Содержание ACS350 Series
Страница 1: ...ACS350 User s Manual ACS350 Drives 0 37 22 kW 0 5 30 HP ...
Страница 4: ......
Страница 8: ...Safety 8 ...
Страница 18: ...Table of contents 18 ...
Страница 24: ...Hardware description 24 ...
Страница 44: ...Installation checklist 44 ...
Страница 56: ...Start up control with I O and ID Run 56 ...
Страница 140: ...Program features 140 ...
Страница 242: ...Actual signals and parameters 242 ...
Страница 266: ...Fieldbus control with embedded fieldbus 266 ...
Страница 284: ...Fault tracing 284 ...
Страница 288: ...Maintenance and hardware diagnostics 288 ...
Страница 309: ...Dimensions 309 Frame size R2 IP20 NEMA 1 3AFE68586658 A Frame size R2 IP20 NEMA 1 VAR EMC ...
Страница 311: ...Dimensions 311 Frame size R3 IP20 NEMA 1 3AFE68579872 B Frame size R3 IP20 NEMA 1 VAR EMC ...
Страница 312: ...Dimensions 312 Frame size R4 IP20 cabinet installation UL open Frame size R4 cabinet installation UL open 3AFE68935644 ...
Страница 313: ......