![background image](http://html.mh-extra.com/html/abb/acs-800-series/acs-800-series_firmware-manual_314198.webp)
Actual signals and parameters
198
42.10
LOW REF BRK HOLD Activates a brake hold function and defines the hold delay for it. The function
stabilises the operation of the brake control application when the motor
operates near zero speed.
0.0 … 60.0 s
0.0 s = inactive.
0.1 s … 60.0 s = active. When the absolute value of the motor speed reference
falls below the brake close speed:
- The brake is closed according to the normal stop routine of the brake control
function
- The brake hold delay counter starts after the brake close delay.
During the delay, the function keeps the brake closed despite the speed
reference value and the value of the Start command. When the set delay has
passed, the normal operation resumes if the absolute speed reference is
greater than the brake close speed.
The following figures explain the two different scenarios that can occur in the
LOW REF BRK HOLD function.
100 = 1 s
Case 1:
The absolute speed reference goes above the brake close speed
before the Low Ref Brk Hold time has elapsed.
Case 2:
The absolute speed reference goes above the brake close speed after
the Low Ref Brk Hold time has elapsed. The brake is opened only after the
speed reference goes above the brake close speed. In this case the brake
immediately opens when the speed ref is greater than the brake close speed,
because the LOW REF BRK HOLD time has already elapsed.
* This time is the additional delay until the speed ref goes above the brake
close speed.
Index
Name/Selection
Description
FbEq
t
Internal Speed Ref.
LOW REF BRK HOLD
BRAKE OPEN CMD
BRAKE CLOSE SPEED
t
Speed Ref.
t
BRAKE CLOSE DELAY
BRAKE OPEN DELAY
t
Internal Speed Ref.
LOW REF BRK HOLD
BRAKE OPEN CMD
BRAKE CLOSE SPEED
t
Speed Ref.
t
BRAKE CLOSE DELAY
*
BRAKE OPEN DELAY
Содержание ACS 800 Series
Страница 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Страница 4: ......
Страница 26: ...Start up and control through the I O interface 26 ...
Страница 36: ...Quick start up guide 36 ...
Страница 52: ...Control panel 52 ...
Страница 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Страница 126: ...Program features 126 The figures below show speed limits according to different load conditions ...
Страница 128: ...Program features 128 ...
Страница 150: ...Application macros control location EXT1 EXT2 150 ...
Страница 228: ...Actual signals and parameters 228 ...
Страница 299: ...Adaptive Programming examples for crane control 299 ...
Страница 305: ...Adaptive Programming examples for crane control 305 ...
Страница 312: ...Adaptive Programming examples for crane control 312 The following figures show the previous example enlarged ...
Страница 314: ...Adaptive Programming examples for crane control 314 The following figures show the previous example enlarged ...
Страница 318: ...Analogue Extension Module 318 ...
Страница 332: ...Additional data actual signals and parameters 332 ...
Страница 333: ...DriveWindow 333 DriveWindow DriveWindow connected to the ACS800 RMIO RDCO board and channel CH3 ...
Страница 334: ...DriveWindow 334 ...
Страница 335: ...Control block diagrams 335 Control block diagrams ...
Страница 336: ...Control block diagrams 336 ...
Страница 337: ...Control block diagrams 337 ...
Страница 338: ...Control block diagrams 338 ...
Страница 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...