Program features
124
Example:
Consider that the motor nominal current is 10 A corresponding to the
base speed of 1500 rpm. Then the parameters are to be configured in the following
sequence.
Note:
The values defined below are only used to define the sequence, and the
actual parameter values have to be entered according to the actual motor details
and the load.
------- 7 A
------- 2000 rpm
------- 8 A
------- 1800 rpm
------- 9 A
------- 1600 rpm
------- 10 A
------- 1500 rpm
Parameters
…
for the reverse direction should also be entered in the
same sequence as shown above. If the sequence of the parameters is not correct,
then the speed is automatically limited to Par.
BASE SPEED, and the error bit
(signal
bit 10) is set to 1.
Example:
This example describes the parameter configuration that can be used for
having a two-speed control. This configuration enables you to run the motor at two
speeds, one being a high speed in the empty hook condition and the other a limited
speed in the load condition.
Note:
The values defined below are considered only to describe the function, and
the actual parameter values have to be entered according to the actual motor details
and the load.
CURR X1 FWD ------- 10 A
REF Y1 FWD ------- 2000 rpm
CURR X2 FWD ------- 12 A
REF Y2 FWD ------- 2000 rpm
CURR X3 FWD ------- 20 A
REF Y3 FWD ------- 1300 rpm
CURR X4 FWD ------- 25 A
REF Y4 FWD ------- 1300 rpm
CURR X1 REV ------- 10 A
REF Y1 REV ------- 2000 rpm
CURR X2 REV ------- 12 A
REF Y2 REV ------- 2000 rpm
CURR X3 REV ------- 20 A
Содержание ACS 800 Series
Страница 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Страница 4: ......
Страница 26: ...Start up and control through the I O interface 26 ...
Страница 36: ...Quick start up guide 36 ...
Страница 52: ...Control panel 52 ...
Страница 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Страница 126: ...Program features 126 The figures below show speed limits according to different load conditions ...
Страница 128: ...Program features 128 ...
Страница 150: ...Application macros control location EXT1 EXT2 150 ...
Страница 228: ...Actual signals and parameters 228 ...
Страница 299: ...Adaptive Programming examples for crane control 299 ...
Страница 305: ...Adaptive Programming examples for crane control 305 ...
Страница 312: ...Adaptive Programming examples for crane control 312 The following figures show the previous example enlarged ...
Страница 314: ...Adaptive Programming examples for crane control 314 The following figures show the previous example enlarged ...
Страница 318: ...Analogue Extension Module 318 ...
Страница 332: ...Additional data actual signals and parameters 332 ...
Страница 333: ...DriveWindow 333 DriveWindow DriveWindow connected to the ACS800 RMIO RDCO board and channel CH3 ...
Страница 334: ...DriveWindow 334 ...
Страница 335: ...Control block diagrams 335 Control block diagrams ...
Страница 336: ...Control block diagrams 336 ...
Страница 337: ...Control block diagrams 337 ...
Страница 338: ...Control block diagrams 338 ...
Страница 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...