Adaptive Programming examples for crane control
301
Brake match
Brake match detects mechanical brake slips and downward movement of the load
when Mechanical brake control is in use, the operator has given the stop command
and the target is to close the brake. The slip detection is based on the motor encoder
position signal, and the function works only if an encoder is used. You can use the
function for an automatic restart of the crane or just for a warning (alarm) indication.
Working logic
The logic checks whether the motor is rotating when the mechanical brake should be
closed. The rotation is detected by comparing two successive position signal
samples (
POS ACT PPU). Therefore, the system needs to be equipped with a
pulse encoder. The logic works during the normal Stop command, extended run
time, and also, when the drive is in the standby (spare unit) mode.
If the position differs between the two successive samples more than set with
parameter
CONSTANT1, and the motor torque is less than the preset value,
Brake match is activated. By means of pointer parameter
ZERO SPEED PTR,
the drive will start with a zero speed reference, and a brake match warning is shown
on the control panel and in the fault logger. You can reset the warning by giving a
new start command: DI1 forward or DI2 reverse. While brake match is active, the
mechanical brake open command is prevented.
For Brake match to work, you need to connect the output of AP block number 10 to
hidden parameter
ZERO SPEED PTR. You can open group 97 by entering
pass code 5600 into parameter
PASS CODE.
The following figures present an example AP file solution for Brake match.
Note:
When creating the actual AP files, you must be pay attention to safety issues
and carefully check the logic case by case.
Содержание ACS 800 Series
Страница 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Страница 4: ......
Страница 26: ...Start up and control through the I O interface 26 ...
Страница 36: ...Quick start up guide 36 ...
Страница 52: ...Control panel 52 ...
Страница 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Страница 126: ...Program features 126 The figures below show speed limits according to different load conditions ...
Страница 128: ...Program features 128 ...
Страница 150: ...Application macros control location EXT1 EXT2 150 ...
Страница 228: ...Actual signals and parameters 228 ...
Страница 299: ...Adaptive Programming examples for crane control 299 ...
Страница 305: ...Adaptive Programming examples for crane control 305 ...
Страница 312: ...Adaptive Programming examples for crane control 312 The following figures show the previous example enlarged ...
Страница 314: ...Adaptive Programming examples for crane control 314 The following figures show the previous example enlarged ...
Страница 318: ...Analogue Extension Module 318 ...
Страница 332: ...Additional data actual signals and parameters 332 ...
Страница 333: ...DriveWindow 333 DriveWindow DriveWindow connected to the ACS800 RMIO RDCO board and channel CH3 ...
Страница 334: ...DriveWindow 334 ...
Страница 335: ...Control block diagrams 335 Control block diagrams ...
Страница 336: ...Control block diagrams 336 ...
Страница 337: ...Control block diagrams 337 ...
Страница 338: ...Control block diagrams 338 ...
Страница 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...